Parametric Search :
It is not compatible with smartphones, so please access it with your computer.
- Display results:
Loading data. Please wait.
Search Model Reset all columns
Total number of products:results Number of applicable products:results Reset | |
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/61559cd9-2c3c-4df6-a3cc-392c690cd028?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 12-24 | 500 | Yes (Fixd) | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | ||||
- | Green mode PWM-IC (Current mode) | PWM | 100 | 12-24 | 500 | Yes (Fixd) | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2dda5b9a-03ce-4e44-886c-ec31a32c34a1?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 12-24 | 500 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | ||||
- | Green mode PWM-IC (Current mode) | PWM | 100 | 12-24 | 500 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | |||||
- | Green mode PWM-IC (Current mode) | PWM | 65 | 12-24 | 500 | Yes (Fixd) | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5edf6e46-3264-4d65-b598-ad6fef024a59?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-28 | 500 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | ||||
- | Green mode PWM-IC (Current mode) | PWM | 65 | 10-28 | 500 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | |||||
- | Green mode PWM-IC (Current mode) | PWM | 65 | 10-28 | 500 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | |||||
- | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | Yes (Fixd) | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | |||||
- | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 650 | Yes (Fixd) | Auto-Recovery | - | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 13 | 6.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ae5330d7-809d-4f3b-ba50-a000599b981a?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 11-24 | 750 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Negative | 18 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5c4bdb7c-4fa4-4131-a1c2-affedf4ff7ef?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 11-24 | 750 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Negative | 18 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/dcb1e861-02aa-47c8-98bb-a82dbc480ba5?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9d39fc05-1b37-4535-b4f0-870d236e4bd8?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8c3e0ce4-5fa0-4931-835c-a55d81ae4f49?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 500 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1b78127f-8ddc-4ec8-b287-f0ace9b5cc84?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 500 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/92cb1f7f-25f8-4dff-8e42-95b5a6ed8171?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/38cf6035-c1f6-44be-be42-2187bee18dbe?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e4d01cc2-550d-4534-aae6-2007dec2591b?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 500 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/16895e31-aea1-4e1e-8335-bb732d4db7f5?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 500 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e1289e10-cdba-415a-a3d1-b6abb06eca33?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 13 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6cb33406-1453-46a7-bdad-552127c403b9?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ef60685b-0c52-4e32-8e11-b1e39e4d50db?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 650 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d8465370-36f3-464b-b780-593682c942e5?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0a1ad92a-dfe7-4677-9816-a5fce7c0b74a?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 650 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | 12.5 | 6.5 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9e12597a-3f08-4276-ac9b-776aea6517d4?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b51a71e6-67a8-40f7-97d8-8944435b7500?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 650 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/337d77ae-bd08-45a4-9fc7-c53cb0882d92?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d35faac2-0202-44bf-9df5-343611659ae5?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 65 | 10-24 | 650 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2ed623a5-4a9b-41b2-b6c8-6c438b0f805e?region=en-glb | - | Green mode PWM-IC (Current mode) | PWM | 100 | 10-24 | 650 | - | Timer-latch | Latch (VCC) | Linerary frequency reduction, Intermittent opration | SOP-8 | Positive | X-Cap discharge | 12.5 | 6.5 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5e851cf5-8738-4825-8202-feff2b1549d2?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | Frequency reduction | SOP-8 | Positive | Frequency reduction at light load | 16.5 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b447a108-3032-44c1-b6af-735f464d0634?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | Frequency reduction | SOP-8 | Negative | Frequency reduction at light load | 16.5 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0eb36764-e82d-46cf-bb69-ec83ca4510c8?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-30 | - | - | Auto-Recovery | Latch (VCC) | - | SOP-8 | Negative | Frequency reduction start/stop FB voltage under light load 1.8V/1.95V | 17.5 | 9.7 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c8f7b602-f949-471f-ad35-37dff7f90a57?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-30 | - | - | Auto-Recovery | Latch (VCC) | - | SOP-8 | Negative | Frequency reduction start/stop FB voltage under light load 1.8V/1.95V | 17.5 | 9.7 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5e982d2a-86f3-4715-8f3d-47a53f90ffe1?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-30 | - | - | Auto-Recovery | Latch (VCC) | - | SOP-8 | Negative | Frequency reduction start/stop FB voltage under light load 1.55V/1.65V | 17.5 | 9.7 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0228124e-f5b8-441e-ab86-3c489a07ac00?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-25 | - | - | - (With Over current protection) | - | - | SOP-8 | Positive | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d256a94f-4b69-4ce9-bd37-a92f3b96b300?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-25 | - | - | - (With Over current protection) | - | - | SOP-8 | Positive | 9.6 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/46cdfa32-c40c-4e8f-abcf-82bd69c93c52?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-25 | - | - | - (With Over current protection) | - | - | SOP-8 | Positive | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f620eca4-b2bf-48a2-b58c-a59d18694ada?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-25 | - | - | - (With Over current protection) | - | - | SOP-8 | Positive | 9.6 | 9 | |||||
- | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | - | SOP-8 | Positive | With error amplifier | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/37c75308-06e9-4306-a6b7-176c1d438dd8?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | - | SOP-8 | Positive | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/afc5d4c9-ab6a-40ed-8ca1-685f686045c9?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | - | SOP-8 | Positive | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/91721710-a238-4716-908a-2b0e8254c434?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | - | SOP-8 | Negative | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/97be7a41-74cb-4de1-b2a8-4c77e89faac5?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-28 | - | - | Timer-latch | Latch (VCC) | Intermittent function | SOP-8 | Negative | 16.5 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3bbcb0bb-d762-4135-be64-142b30d2f534?region=en-glb | - | General PWM-IC | PWM | Adjustable | 10-30 | - | - | Auto-Recovery | Latch (VCC) | Intermittent function | SOP-8 | Negative | Overcurrent limit correction function | 17.5 | 9.7 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0c270b69-3104-4ab8-94a7-84f6d5b7c9b0?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Auto-Recovery | - | Intermittent function | SOP-8 | Positive | 18 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8d003d53-a9e9-4843-9576-f65048fa71c8?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | Over voltage protection, Latch | 18 | 8 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b852d967-e984-4eef-8300-e6b9a4f831cd?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Timer-latch | Latch(ZCD) | Intermittent function | SOP-8 | Positive | 18 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c6d412da-fd99-4165-97a2-624bb05aa5a9?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Auto-Recovery | Latch(ZCD) | Linerary frequency reduction | SOP-8 | Positive | 18 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4a466546-cdd6-4901-8132-99d0474883d7?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Timer-latch | Latch(ZCD) | Linerary frequency reduction | SOP-8 | Positive | 18 | 8 | |||||
- | Green mode Quasi-resonant IC (Current mode) | QR | 120 | 10-28 | 500 | - | Auto-Recovery | Latch (VCC) | Linerary frequency reduction | SOP-8 | Positive | 18 | 8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/396b4e8c-aa16-442e-99b8-d335de02198f?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | 14 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d21a74af-0174-402d-a1a5-f44076aafee1?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | Min. frequency limitation | 14 | 8 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/eebb82bc-7ffe-4188-9cc9-70cbe0471b37?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | 10 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a8ccce9c-13b2-4b0b-8f7b-fb542c90a3bb?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | Min. frequency limitation, Latch stop function (IS pin) | 14 | 8 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e1d41de3-aad1-4b31-b320-fda083a7af81?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Timer-latch | Latch(ZCD) | Intermittent function | SOP-8 | Positive | 14 | 8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7e8701b4-1811-462a-8eaa-7d678d365959?region=en-glb | - | Green mode Quasi-resonant IC (Current mode) | QR | Self-oscillation (With bottom skip control function) | 11-26 | 500 | - | Auto-Recovery | Latch(ZCD) | Intermittent function | SOP-8 | Positive | For High SW frequency | 14 | 8 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d30b84fa-266e-423a-82ab-fde22579856f?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Max. frequency limitation | SOP-8 | Negative | 9.6 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/14ff011c-bb1e-46bf-8775-95fd39878eed?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Max. frequency limitation | SOP-8 | Negative | 13 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/187914c2-6e97-42b2-8e95-6b962531b1e2?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Negative | 9.6 | 8.8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f0c8f6e3-a046-4fb4-805d-7d5f82949240?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Negative | 12.4 | 8.8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f56d460e-92e5-4639-a8cf-2b4704922ebd?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Negative | 9.6 | 8.8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b69d8760-2219-45b4-bcbf-30b6cbfe669c?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction, Intermittent function | SOP-8 | Negative | Improve light load efficiency, Cooperate with FA6B19N/20N/22N | 12.5 | 7.5 | ||||
- | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | SOP-8 | Negative | Improve transient response, Cooperate with FA6B21N | 12.5 | 7.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e64a3937-2dcc-4d4b-8f6f-a23f378d87f2?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Max. frequency limitation | SOP-8 | Negative | 9.6 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e4371e1b-8caa-4293-8ec3-0f7a0f014067?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Negative | 9.6 | 8.8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/50cc5c90-8f20-4b20-9f36-21c6da89d117?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Negative | 12.4 | 8.8 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7b903ce8-a563-4cf0-9a5c-fd52e626bc04?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Max. frequency limitation | SOP-8 | Positive | 13 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5510eb18-2372-49cd-9ed3-16cf0a250584?region=en-glb | - | Power factor correction IC | CRM-PFC | Self-oscillation | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | Frequency reduction | SOP-8 | Positive | For fly back over load protection | 17.3 | 9.6 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1fda2ecd-a35f-4dbd-b25b-1733ce02af5d?region=en-glb | - | Power factor correction IC | CCM-PFC | Adjustable | 10-28 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-16(M) | Negative | 16.5 | 8.9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a23b0328-bfae-4130-a2e8-b58b2ec9a7ab?region=en-glb | - | Power factor correction IC | CCM-PFC | Adjustable 60/65kHz/jitter(50-70kHz) | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-8 | Negative | Frequency diffusion function | 9.6 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f08defe1-461c-45e1-b60e-ca39b638359b?region=en-glb | - | Power factor correction IC | CCM-PFC | Adjustable 60/65kHz/jitter(50-70kHz) | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-8 | Negative | Frequency diffusion function | 13 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ea416467-1fa2-4b92-b7bb-bd2c807680ca?region=en-glb | - | Power factor correction IC | CCM-PFC | Adjustable 120/130kHz/jitter(106-148kHz) | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-8 | Negative | Frequency diffusion function | 9.6 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d8cf6bcf-6e0a-4fb9-8d16-99656fa50eba?region=en-glb | - | Power factor correction IC | CCM-PFC | Adjustable 120/130kHz/jitter(106-148kHz) | 10-26 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-8 | Negative | Frequency diffusion function | 13 | 9 | ||||
- | Current Resonant IC | LLC | Self-oscillation | 14-27 | 600 | Yes (Fixd) | Auto-Recovery | Latch (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 12 | 9 | |||||
- | Current Resonant IC | LLC | Self-oscillation | 14-27 | 600 | Yes (Ajustable) | Auto-Recovery | Latch (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 12 | 9 | |||||
- | Current Resonant IC | LLC | Self-oscillation | 14-27 | 600 | Yes (Ajustable) | Timer-latch | Latch (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 12 | 9 | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5ea92c82-ccb3-405c-b790-d6f406a25d8c?region=en-glb | - | Current Resonant IC | LLC | Self-oscillation | 14-27 | 600 | Yes (Ajustable) | Auto-Recovery | Latch (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 13 | 9 | ||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ab25f197-d222-4c87-99ab-f4891ab71442?region=en-glb | - | Current Resonant IC | LLC | Self-oscillation | 14-27 | 600 | Yes (Ajustable) | Timer-latch | Latch (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 13 | 9 | ||||
- | Current Resonant IC | LLC | Self-oscillation | 14-29 | 600 | Yes (Fixd) | Auto-Recovery | Auto-Recovery (VCC) | SOP-16(N) | Positive-Negative | 14 | 9 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b78c24e5-73df-476c-9b66-a05c1cb1159d?region=en-glb | - | Current Resonant IC | LLC | Self-oscillation | 14-29 | 600 | Yes (Fixd) | Auto-Recovery | Auto-Recovery (VCC) | Intermittent function | SOP-16(N) | Positive-Negative | X-Cap discharge | 14 | 9 | ||||
- | Current Resonant IC | LLC | Self-oscillation | 14-29 | 600 | Yes (Fixd) | Auto-Recovery | Auto-Recovery (VCC) | SOP-16(N) | Positive-Negative | X-Cap discharge | 14 | 9 | ||||||
- | Current Resonant IC | LLC | Self-oscillation | 14-29 | 600 | Yes (Fixd) | Auto-Recovery | Auto-Recovery (VCC) | SOP-16(N) | Positive-Negative | X-Cap discharge | 14 | 9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/fad59c8d-b559-4814-a963-2369b5585868?region=en-glb | New | Power factor correction IC | CRM-PFC | Self-oscillation | 10-24 | - | - | - (With Over current protection) | Auto-Recovery (FB) | - | SOP-8 | Positive | 13 | 9 |
Customize row
Drag and drop to move items from displayed and hidden columns.
Display order can be changed. Multiple selections are also possible.
Reset row customization?
- Cancel
- Reset