https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/05e1135d-0795-412b-b480-13c0d3c6c7b3?region=en-glb | SBD | Single | 40 | 5 | 80 | 0.55 | 5 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4970878f-0aee-4212-a5f9-e6779d275521?region=en-glb | SBD | Single | 40 | 5 | 120 | 0.55 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3341cce4-4dae-46c3-b024-37c80e3f1a03?region=en-glb | SBD | Single | 45 | 10 | 120 | 0.6 | 2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/db7c7b18-b99c-477a-8cc0-c04690e05393?region=en-glb | SBD | Single | 60 | 5 | 80 | 0.59 | 5 | TO-220F | 150 | 1.7 | ||||||
SBD | Single | 60 | 15 | 120 | 0.63 | 20 | TO-220F | 150 | 1.7 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/aab45ea2-bdf4-49a4-a69b-d05fa9886092?region=en-glb | SBD | Dual | 20 | 7 | 60 | 0.39 | 10 | K-Pack(L) | 125 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1b26ff5e-cc70-4530-9a88-818f6a5e864b?region=en-glb | SBD | Dual | 20 | 7 | 60 | 0.39 | 10 | K-Pack(S) | 125 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/cbf7e769-06c2-4c51-8ba9-4de304580d3a?region=en-glb | SBD | Dual | 30 | 5 | 60 | 0.47 | 5 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0c9cb889-8265-4615-928a-e9cdb39dd41b?region=en-glb | SBD | Dual | 40 | 5 | 60 | 0.55 | 5 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5b436e2c-40a9-430b-a380-f1f0d30098fc?region=en-glb | SBD | Dual | 40 | 5 | 100 | 0.55 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/fced8706-3db8-4beb-9472-2fae3b7c841d?region=en-glb | SBD | Dual | 40 | 10 | 120 | 0.55 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b4890745-0cd9-4388-99c9-3520302bedef?region=en-glb | SBD | Dual | 40 | 20 | 120 | 0.6 | 15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c82a4444-473d-4503-919a-49898be114a3?region=en-glb | SBD | Dual | 40 | 30 | 180 | 0.53 | 8 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/86dabfdb-f3ff-43cb-b3a9-516415533faa?region=en-glb | SBD | Dual | 40 | 30 | 180 | 0.53 | 8 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7c69973c-69a8-486a-bd2c-4b88fba32df1?region=en-glb | SBD | Dual | 60 | 5 | 60 | 0.58 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1896ec06-2175-450f-8946-1f60e678376e?region=en-glb | SBD | Dual | 60 | 10 | 80 | 0.58 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/08a3e77b-5b91-4dad-99c4-54fefeea27be?region=en-glb | SBD | Dual | 60 | 15 | 100 | 0.58 | 5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e518d4f1-8782-48fe-bb32-bd640e166809?region=en-glb | SBD | Dual | 60 | 20 | 80 | 0.58 | 15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/42a0f2bc-7dfd-4d04-9002-889bb826fe19?region=en-glb | SBD | Dual | 60 | 30 | 150 | 0.58 | 3 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f11acde5-a570-4d2c-bec6-dba38c242a21?region=en-glb | SBD | Dual | 90 | 5 | 60 | 0.9 | 5 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f6693d66-69d1-4816-bf7d-8b77e01bb2dd?region=en-glb | SBD | Dual | 100 | 5 | 60 | 0.8 | 0.7 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e13c7d53-f722-405e-b782-56bca0736867?region=en-glb | SBD | Dual | 100 | 10 | 80 | 0.8 | 1.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4e551a66-64ba-494d-b6f7-c7f78b788a90?region=en-glb | SBD | Dual | 100 | 20 | 100 | 0.8 | 2.5 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a9d37d3e-c8d0-45ba-8ccc-4e53653ad21a?region=en-glb | SBD | Dual | 100 | 30 | 180 | 0.8 | 20 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a24f1e3e-ea6c-4b78-ab36-ac16fbdc169b?region=en-glb | SBD | Dual | 40 | 10 | 120 | 0.55 | 5 | T-Pack(L) | 150 | 1.6 | ||||||
SBD | Dual | 40 | 10 | 120 | 0.55 | 5 | T-pack(S) | 150 | 1.6 | |||||||
SBD | Dual | 40 | 20 | 120 | 0.6 | 15 | T-pack(S) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c830be0b-49ed-471d-9f85-e02ea22ba275?region=en-glb | SBD | Dual | 40 | 30 | 150 | 0.55 | 20 | TO-3PF | 150 | 6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8ea21ffe-3ec0-44d2-b22d-578963d1e72a?region=en-glb | SBD | Dual | 40 | 30 | 150 | 0.55 | 20 | TO-3P | 150 | 5.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0bbf57bc-3501-4775-ac87-9aa136373b70?region=en-glb | SBD | Dual | 60 | 30 | 120 | 0.58 | 20 | TO-3PF | 150 | 6 | ||||||
SBD | Dual | 60 | 30 | 120 | 0.58 | 20 | T-pack(S) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/25e01de7-b649-4c3d-a5a0-aa075052ab8d?region=en-glb | SBD | Dual | 60 | 30 | 120 | 0.58 | 20 | TO-3P | 150 | 5.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6694339b-5cce-4922-9544-10195fa5cae3?region=en-glb | SBD | Dual | 100 | 10 | 125 | 0.82 | 0.015 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7572e62e-716a-4995-94ab-7adc3b5461d9?region=en-glb | SBD | Dual | 100 | 10 | 125 | 0.82 | 0.015 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/bf3393cc-9f10-4c6a-9a58-40183599d935?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.02 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/386977a7-d913-406a-ba64-628134a8f32b?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.02 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f8c12b89-5d1a-4914-8518-4bf9e3594b1c?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.03 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/745c2511-efd3-483f-a5ea-27770d921d92?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.03 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8f4a22f1-f2d8-4903-b564-c170d95110ff?region=en-glb | SBD | Dual | 120 | 10 | 125 | 0.84 | 0.015 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e8c9c661-9c7c-4286-bff2-fea8d4e77ae5?region=en-glb | SBD | Dual | 120 | 10 | 125 | 0.84 | 0.015 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/135f2bc3-ed95-4beb-989d-4185c31c9ecb?region=en-glb | SBD | Dual | 120 | 20 | 145 | 0.88 | 0.02 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4676aa11-32d7-4418-be45-447f4cbcd172?region=en-glb | SBD | Dual | 120 | 20 | 145 | 0.88 | 0.02 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/de9a3811-82b8-4291-bc3a-b4be4bb4fda7?region=en-glb | SBD | Dual | 120 | 30 | 160 | 0.88 | 0.03 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/28ab81ad-2d9b-4863-91b7-7e80c0d58b22?region=en-glb | SBD | Dual | 120 | 30 | 160 | 0.88 | 0.03 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/cafeb5b1-2154-4e6e-a4b4-33c104edf1ac?region=en-glb | SBD | Dual | 150 | 10 | 125 | 0.86 | 0.015 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1d5f8f97-13b6-48a4-a292-c9fb6d19994f?region=en-glb | SBD | Dual | 150 | 10 | 125 | 0.86 | 0.015 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b6c93fb1-caba-4dad-8023-f128294a2db3?region=en-glb | SBD | Dual | 150 | 20 | 145 | 0.89 | 0.02 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/73db5e44-c1d7-4b95-8690-092d6a595329?region=en-glb | SBD | Dual | 150 | 20 | 145 | 0.89 | 0.02 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/daaf4d78-5c0d-4e8a-a00d-23cc6978a151?region=en-glb | SBD | Dual | 150 | 30 | 160 | 0.89 | 0.03 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/00864e04-7c12-4113-99f2-be74465e7059?region=en-glb | SBD | Dual | 150 | 30 | 160 | 0.89 | 0.03 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/330906cc-8423-4738-9709-3b5b601f8b16?region=en-glb | SBD | Dual | 200 | 10 | 125 | 0.89 | 0.015 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/457e7fee-4aa3-4723-9aeb-7cfa3fa7ef2a?region=en-glb | SBD | Dual | 200 | 10 | 125 | 0.89 | 0.015 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b6a5d41a-f2a2-4ced-b2fb-e1d2132b7067?region=en-glb | SBD | Dual | 200 | 20 | 145 | 0.93 | 0.02 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ea25959f-391d-404b-854a-52e302ef8a22?region=en-glb | SBD | Dual | 200 | 20 | 145 | 0.93 | 0.02 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/38fa9ad2-57a8-4097-8fca-058a751641cb?region=en-glb | SBD | Dual | 200 | 30 | 160 | 0.93 | 0.03 | TO-220F | 175 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/81b5c1d9-c268-4390-b09b-31c2c296ca31?region=en-glb | SBD | Dual | 200 | 30 | 160 | 0.93 | 0.03 | TO-220 | 175 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5503e5b5-18ce-4a5c-95ce-fa563d613dd2?region=en-glb | SBD | Single | 120 | 5 | 75 | 0.88 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/44d8d00a-8864-4009-b271-b6febfb6cdbb?region=en-glb | SBD | Single | 150 | 5 | 75 | 0.9 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/652b91f2-7407-43ba-92cc-b3ada91fa35d?region=en-glb | SBD | Dual | 45 | 20 | 145 | 0.63 | 0.175 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/df177da2-c3e0-4886-bf6d-e660d27aa23c?region=en-glb | SBD | Dual | 45 | 20 | 145 | 0.63 | 0.175 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f443ceff-595c-4843-9412-6e80330caa39?region=en-glb | SBD | Dual | 45 | 20 | 145 | 0.63 | 0.175 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ed4d0f2a-447f-4135-a965-1dfd160e3bd7?region=en-glb | SBD | Dual | 45 | 20 | 145 | 0.63 | 0.175 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/95ecf6ef-ec15-4095-b989-b49cce730b27?region=en-glb | SBD | Dual | 45 | 30 | 160 | 0.63 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3982da38-5c9a-474b-8880-1009b194ece9?region=en-glb | SBD | Dual | 45 | 30 | 160 | 0.63 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0305cf5e-9a5f-4b96-80f7-cfe173309aeb?region=en-glb | SBD | Dual | 45 | 30 | 160 | 0.63 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7f73bbb5-2089-4338-9a7f-2119cd1d1aa1?region=en-glb | SBD | Dual | 45 | 30 | 160 | 0.63 | 0.2 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5b3cbe14-6d3d-48f7-98b4-2d4218b634f7?region=en-glb | SBD | Dual | 60 | 10 | 125 | 0.68 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6b8b07eb-7806-4a30-82bf-adaf5dd3cdcd?region=en-glb | SBD | Dual | 60 | 10 | 125 | 0.68 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3d22eb4a-16e7-4688-8980-87879fb9a572?region=en-glb | SBD | Dual | 60 | 10 | 125 | 0.68 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b55803d8-9922-4ccd-bc26-e41ac52e722f?region=en-glb | SBD | Dual | 60 | 20 | 145 | 0.74 | 0.175 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ff3ad920-a186-482b-b0f3-80289b2145d5?region=en-glb | SBD | Dual | 60 | 20 | 145 | 0.74 | 0.175 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2e019c4b-3afa-4ff7-9cd8-d859be689126?region=en-glb | SBD | Dual | 60 | 20 | 145 | 0.74 | 0.175 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b4ccd848-c54c-406d-b1d3-2eb1839041b3?region=en-glb | SBD | Dual | 60 | 30 | 160 | 0.74 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/749a8bef-0d28-431b-8db4-d7f7d43a1a09?region=en-glb | SBD | Dual | 60 | 30 | 160 | 0.74 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/518f396c-d5ab-420f-804c-468f9f2d2f3b?region=en-glb | SBD | Dual | 60 | 30 | 160 | 0.74 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1b0c7413-1975-4c8c-8be2-a9dc61d2cfe6?region=en-glb | SBD | Dual | 60 | 40 | 190 | 0.7 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a0c5f69a-7f5c-474b-a3bf-c35478e8afb3?region=en-glb | SBD | Dual | 60 | 40 | 190 | 0.7 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/cdff54c5-4c40-4b2b-8efe-270dfc7f12bc?region=en-glb | SBD | Dual | 60 | 40 | 190 | 0.7 | 0.2 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/44561f55-4a11-42c5-9643-f95193e854bd?region=en-glb | SBD | Dual | 80 | 10 | 125 | 0.76 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9ab86ba8-1a38-45b8-a580-5ab31aba2cc4?region=en-glb | SBD | Dual | 80 | 10 | 125 | 0.76 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8c612da8-9309-497a-81bb-f34c5b63f575?region=en-glb | SBD | Dual | 80 | 10 | 125 | 0.76 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/de36ca84-fb90-4f43-a2d8-042fb7c75ea6?region=en-glb | SBD | Dual | 80 | 10 | 125 | 0.76 | 0.15 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c7bb8ab4-203c-4645-9fd2-ab1f4b0e6fc1?region=en-glb | SBD | Dual | 80 | 20 | 145 | 0.76 | 0.175 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/10c83547-821c-4576-bf33-3a83a494681d?region=en-glb | SBD | Dual | 80 | 20 | 145 | 0.76 | 0.175 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6dfdd186-b6ad-4b76-bdb8-594ccfdc25b8?region=en-glb | SBD | Dual | 80 | 20 | 145 | 0.76 | 0.175 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ef6760b6-d872-4c76-b7ed-361257e989be?region=en-glb | SBD | Dual | 80 | 20 | 145 | 0.76 | 0.175 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/217b9f67-7f88-4e02-a35e-57b995dd92ec?region=en-glb | SBD | Dual | 80 | 30 | 160 | 0.76 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/14bef662-8432-4af7-baeb-a690aea920aa?region=en-glb | SBD | Dual | 80 | 30 | 160 | 0.76 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4ae76bd1-3457-4c2f-95b1-91e9f1ee432e?region=en-glb | SBD | Dual | 80 | 30 | 160 | 0.76 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/51d04620-1a8b-422d-b4a3-4dd165087d58?region=en-glb | SBD | Dual | 80 | 40 | 190 | 0.71 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/aa5da7e5-0931-4260-a1d1-a0ce29d97ff5?region=en-glb | SBD | Dual | 80 | 40 | 190 | 0.71 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/80667f1c-ab26-4150-b395-a4be0a0facab?region=en-glb | SBD | Dual | 80 | 40 | 190 | 0.71 | 0.2 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f075c5ff-c2de-4c98-a031-fc6f2e3f7058?region=en-glb | SBD | Dual | 100 | 10 | 125 | 0.86 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d4ca1265-6c91-44f3-8429-e8638772c76c?region=en-glb | SBD | Dual | 100 | 10 | 125 | 0.86 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7d92ed3f-faed-476d-8c7b-dd0a58399d15?region=en-glb | SBD | Dual | 100 | 10 | 125 | 0.86 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d12b7245-de61-40ed-ab6c-d6ad4fdcfb1d?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.175 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/23180b20-ecb3-4fe3-a43c-2edd44dbbb63?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.175 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5f432228-6864-46ba-916b-a8eb4fb223d5?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.175 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6843b39f-5ec0-42a5-bfd6-0d1e2ec38519?region=en-glb | SBD | Dual | 100 | 20 | 145 | 0.86 | 0.175 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e017d9c6-165d-4f05-a788-f25e4ecdf540?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/bbf213ec-2b22-41f5-b286-b60d6be42d59?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1213bf71-6d29-4917-a988-26ef0456aa2b?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e952a836-8539-48a6-88e9-1055d02b2463?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/737780f2-3ab4-4b75-951d-20f5c3bc72c8?region=en-glb | SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | TFP | 150 | 0.8 | ||||||
SBD | Dual | 100 | 30 | 160 | 0.86 | 0.2 | TO-3P(Q) | 150 | 5.1 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1c3b6110-141b-4e81-9dcf-27f7e0f872bc?region=en-glb | SBD | Dual | 100 | 40 | 190 | 0.82 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5d83e2eb-5c47-4153-8edc-29360f717f43?region=en-glb | SBD | Dual | 100 | 40 | 190 | 0.82 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2ce87636-3e40-451a-a962-0e46eaabd660?region=en-glb | SBD | Dual | 100 | 40 | 190 | 0.82 | 0.2 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3e79f9cb-7d90-4ef3-9757-7592ade0eaf2?region=en-glb | SBD | Dual | 120 | 10 | 75 | 0.88 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6bc0ca48-7f47-4eaf-b892-25a65fcb49d1?region=en-glb | SBD | Dual | 120 | 10 | 75 | 0.88 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ec388e8c-6b53-4cdd-96c1-8f91d7656d80?region=en-glb | SBD | Dual | 120 | 10 | 75 | 0.88 | 0.15 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ec98622e-1012-4854-aea5-9fce8e9cc631?region=en-glb | SBD | Dual | 120 | 10 | 75 | 0.88 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/fe492a35-1da3-4564-9a17-2dcbf2bc925e?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/49b245db-7c21-4479-b5cd-599ed4b32ffd?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b3ed58c8-1f11-48ef-adcf-3833e8fc951f?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | TO-247(Type:A) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/10d5bfb2-8be7-43a5-9702-a4dc7c6671b4?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c78f58c7-2ca4-437f-8213-8f89d3738672?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9594e758-bf72-468c-be27-7ed79d99f38d?region=en-glb | SBD | Dual | 120 | 20 | 150 | 0.88 | 0.15 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/54bda9b8-e0cd-42f7-93bc-04235e963339?region=en-glb | SBD | Dual | 120 | 30 | 190 | 0.88 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5bd116b1-1234-4019-b7ad-755f7e41f834?region=en-glb | SBD | Dual | 120 | 30 | 190 | 0.88 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6cf79505-c228-4400-b9b2-cd70d29c93d3?region=en-glb | SBD | Dual | 120 | 30 | 190 | 0.88 | 0.2 | TO-247(Type:A) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/06d58887-4215-4be6-9228-d4f9712c4f0d?region=en-glb | SBD | Dual | 120 | 30 | 190 | 0.88 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/61be43c8-d03e-4ec4-95ab-8715ff336057?region=en-glb | SBD | Dual | 120 | 30 | 190 | 0.88 | 0.2 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/00c6f326-8030-444e-9132-7cbaa96677ea?region=en-glb | SBD | Dual | 120 | 40 | 190 | 0.95 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/25c3d3e4-2b53-4c63-8293-123a5568e3d7?region=en-glb | SBD | Dual | 120 | 40 | 190 | 0.95 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/588535d5-2617-48bb-8264-d1740d16744b?region=en-glb | SBD | Dual | 150 | 10 | 75 | 0.9 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b9b52e84-478c-4294-bf9d-e51e61e8ea29?region=en-glb | SBD | Dual | 150 | 10 | 75 | 0.9 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/724e121a-38e5-48f2-8c35-77da1b6c24a2?region=en-glb | SBD | Dual | 150 | 10 | 75 | 0.9 | 0.15 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/26956f36-cd4e-4717-ade8-73cb29ae9d3f?region=en-glb | SBD | Dual | 150 | 10 | 75 | 0.9 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/77553f38-1789-4b48-85fd-74fb9d86b512?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/36e666cb-1ccc-49fd-bc04-097f361d9eba?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | TO-247(Type:A) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0852dce4-03cf-47eb-863f-21fca1e928df?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | TO-3PF | 150 | 6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/542b6a2e-ce34-455b-8beb-6dbfec598918?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ff48b018-4182-4d31-86ed-73d31fc75942?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | T-Pack(L) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8f98ebad-1285-493c-aacc-1c65f4aaf869?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/bab14193-59eb-4141-8b48-233817072707?region=en-glb | SBD | Dual | 150 | 20 | 150 | 0.9 | 0.15 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8584b50c-0fb8-4e80-a445-b9c8f1479fa3?region=en-glb | SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/be8a216f-5bda-46e0-b89a-f1a73d26232e?region=en-glb | SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/abf6a0a7-0ab8-412f-bf31-58cf417a935e?region=en-glb | SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/953e5610-ed91-4359-bbcf-9c612056ccd0?region=en-glb | SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | TFP | 150 | 0.8 | ||||||
SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | TO-3P | 150 | 5.5 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d666a453-2b7e-47d2-b0bd-94af19db3a19?region=en-glb | SBD | Dual | 150 | 30 | 190 | 0.9 | 0.2 | TO-247(Type:A) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e29a82f4-5059-4e5f-a9ad-01722a6c19db?region=en-glb | SBD | Dual | 150 | 40 | 190 | 0.97 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ecdbdbf6-1ea4-4296-ac36-9e562ead5b79?region=en-glb | SBD | Dual | 150 | 40 | 190 | 0.97 | 0.2 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/90b06073-93cb-426d-8de1-fc63d433c633?region=en-glb | LLD (CRM-PFC) | Single | 600 | 8 | 70 | 1.55 | 0.01 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e0e00de4-1ac8-447e-af3d-e6e5014b7849?region=en-glb | LLD (CRM-PFC) | Single | 600 | 8 | 70 | 1.55 | 0.01 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7594eb54-fb74-44f1-a84b-7ed75a665b01?region=en-glb | LLD (CRM-PFC) | Single | 600 | 10 | 100 | 1.55 | 0.01 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/f7ba199f-0458-4c74-9dec-81212da28365?region=en-glb | LLD (CRM-PFC) | Single | 600 | 10 | 100 | 1.55 | 0.01 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/01c8f39b-e3ea-4735-95cd-51a8ed1cef03?region=en-glb | LLD (CRM-PFC) | Single | 800 | 5 | 60 | 2.2 | 0.01 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c65f6d19-1d4b-4a3e-9539-1ee107378a91?region=en-glb | LLD (CRM-PFC) | Dual | 600 | 20 | 100 | 1.55 | 0.01 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c6ec1377-9b89-452a-ac61-2d627ffdc9b6?region=en-glb | LLD (CRM-PFC) | Dual | 600 | 20 | 100 | 1.55 | 0.01 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a0fc8839-985c-4140-975f-c0ee629bb24c?region=en-glb | LLD (CRM-PFC) | Dual | 600 | 20 | 100 | 1.55 | 0.01 | TO-247(Type:A) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1e836347-fb6e-414d-8027-2fa4c78e621c?region=en-glb | LLD (CCM-PFC) | Single | 600 | 8 | 40 | 3 | 0.025 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d74b6438-cde1-47df-8113-e5153fa68d84?region=en-glb | LLD (CCM-PFC) | Single | 600 | 8 | 40 | 3 | 0.025 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ec13cb9e-f116-4353-b82d-c3f180a49174?region=en-glb | LLD (CCM-PFC) | Single | 600 | 10 | 50 | 3 | 0.03 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1a701257-f054-4579-9431-e300ad63ff34?region=en-glb | LLD (CCM-PFC) | Single | 600 | 10 | 50 | 3 | 0.03 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d0eda196-705c-4f38-82d8-2cea10b8777a?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 16 | 40 | 3 | 0.025 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/75c356fe-8e83-484a-8ee8-9bf4b99ffbd1?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 16 | 40 | 3 | 0.025 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5b4a7a88-bc5c-4b6d-a1b7-745b0a20724f?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 16 | 40 | 3 | 0.025 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8752c809-b9f5-47ff-b56c-f3cca05cede1?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 20 | 50 | 3 | 0.03 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/97cbc796-f6c0-46a4-9789-0468a74faba3?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 20 | 50 | 3 | 0.03 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0e05a18d-6d41-4c87-a7b1-6f2c6574c3c7?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 20 | 50 | 3 | 0.03 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ad34abf6-50df-4b5f-88d5-bde83ff4d64b?region=en-glb | LLD (CCM-PFC) | Dual | 600 | 20 | 50 | 3 | 0.03 | TO-247(Type:A) | 150 | 4.9 | ||||||
LLD | Single | 200 | 5 | 70 | 0.95 | 0.1 | K-Pack(L) | 150 | 0.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e619497f-0935-4c4b-a568-6bbd123c8b39?region=en-glb | LLD | Single | 200 | 5 | 70 | 0.95 | 0.1 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5d559417-16eb-4df9-bc86-59a3c6be482b?region=en-glb | LLD | Single | 200 | 5 | 50 | 0.95 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a49d198d-54f2-42dd-a5fe-26130fe0889c?region=en-glb | LLD | Single | 200 | 10 | 80 | 0.98 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8cf15511-992b-4627-a083-8f590929e7ef?region=en-glb | LLD | Single | 300 | 5 | 40 | 1.2 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/21f181a7-719b-40a1-8222-2652f2224b5c?region=en-glb | LLD | Dual | 200 | 5 | 50 | 0.95 | 0.1 | K-Pack(L) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2f54f8c5-bc5d-4ad6-916f-e0d9045a7bfb?region=en-glb | LLD | Dual | 200 | 5 | 50 | 0.95 | 0.1 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/51fc784b-98ee-44ee-8c6b-b6dd255ff12a?region=en-glb | LLD | Dual | 200 | 5 | 25 | 0.95 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4b769099-3245-436e-9202-91f2fed3d052?region=en-glb | LLD | Dual | 200 | 10 | 50 | 0.95 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d8b4a5a1-7f83-48d6-9fca-34f4678a1c32?region=en-glb | LLD | Dual | 200 | 20 | 80 | 0.98 | 0.2 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/bb40d82c-d77e-429b-9a56-8de3a6b8ee78?region=en-glb | LLD | Dual | 200 | 20 | 80 | 0.98 | 0.2 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4ee9682d-7187-460f-b2b4-9412005d6b8e?region=en-glb | LLD | Dual | 300 | 5 | 25 | 1.2 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/dc0cd22e-ef39-4d6b-a354-9c78d20e1988?region=en-glb | LLD | Dual | 300 | 10 | 40 | 1.2 | 0.1 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/951c4c22-a974-47b3-a9b2-af9b67684689?region=en-glb | LLD | Dual | 300 | 20 | 80 | 1.2 | 0.2 | TFP | 150 | 0.8 | ||||||
LLD | Dual | 200 | 5 | 25 | 0.95 | 0.1 | T-Pack(L) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7e1aaa6e-fd32-4d50-9d17-dce86bd81432?region=en-glb | LLD | Dual | 200 | 10 | 50 | 0.95 | 0.1 | T-Pack(L) | 150 | 1.6 | ||||||
LLD | Dual | 200 | 10 | 50 | 0.95 | 0.1 | T-Pack(S) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2ff4e502-93ca-4e0c-964c-b9c09d34bc20?region=en-glb | LLD | Dual | 200 | 20 | 100 | 0.95 | 0.2 | TO-3PF | 150 | 6 | ||||||
LLD | Dual | 200 | 20 | 80 | 0.98 | 0.2 | T-Pack(L) | 150 | 1.6 | |||||||
LLD | Dual | 200 | 20 | 80 | 0.98 | 0.2 | T-Pack(S) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0e536e6e-490b-42f6-856c-4b7d4459b25d?region=en-glb | LLD | Dual | 200 | 20 | 100 | 0.95 | 0.2 | TO-3P | 150 | 5.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5a4f448c-3b30-45f0-a9bd-08956998212f?region=en-glb | LLD | Dual | 300 | 10 | 40 | 1.2 | 0.1 | T-Pack(L) | 150 | 1.6 | ||||||
LLD | Dual | 300 | 10 | 40 | 1.2 | 0.1 | T-Pack(S) | 150 | 1.6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/cc32be03-b607-4dff-94b9-72f63bb08d98?region=en-glb | LLD | Dual | 300 | 20 | 80 | 1.2 | 0.2 | TO-3P | 150 | 5.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e25f02ea-6f7c-4d7a-a972-d0f66f7ccb69?region=en-glb | LLD | Dual | 300 | 20 | 80 | 1.2 | 0.2 | TO-3PF | 150 | 6 | ||||||
LLD | Dual | 300 | 30 | 115 | 1.2 | 0.3 | TO-3P | 150 | 5.5 | |||||||
LLD | Dual | 300 | 60 | 240 | 1.2 | 0.6 | TO-3P | 150 | 5.5 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2cb44950-0c58-45b3-a4a3-790493304b73?region=en-glb | LLD | Dual | 400 | 20 | 70 | 1.5 | 0.5 | TO-3P | 150 | 5.5 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/b9fe48d4-d538-43dc-bd6d-2e16757127a4?region=en-glb | LLD | Single | 300 | 5 | 90 | 1.3 | 0.02 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/736ce8e6-dac7-41b1-89d3-c0e4b4ad001a?region=en-glb | LLD | Single | 400 | 5 | 80 | 1.45 | 0.02 | K-Pack(S) | 150 | 0.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ea17e14e-9826-4e58-8423-e13f9b96ed1d?region=en-glb | LLD | Dual | 300 | 10 | 90 | 1.3 | 0.02 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3e9cf429-64db-482f-ac48-c48a23ef0d47?region=en-glb | LLD | Dual | 300 | 10 | 90 | 1.3 | 0.02 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/501f0c5f-54a2-494d-8c32-c86604b64066?region=en-glb | LLD | Dual | 300 | 10 | 90 | 1.3 | 0.02 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/908c1676-84d5-45ba-ac25-8b4a78de3b5a?region=en-glb | LLD | Dual | 300 | 20 | 110 | 1.3 | 0.035 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/58c72aa8-7dcc-4fff-9f91-94acc29c23b3?region=en-glb | LLD | Dual | 300 | 20 | 110 | 1.3 | 0.035 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/61477090-bf79-4ba5-9293-4221e870a2e6?region=en-glb | LLD | Dual | 300 | 20 | 110 | 1.3 | 0.035 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9a8d9934-86e0-491e-8636-39f474e6b3e0?region=en-glb | LLD | Dual | 300 | 20 | 110 | 1.3 | 0.035 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/3e731dbf-492e-4ef6-af23-94e99c08799a?region=en-glb | LLD | Dual | 300 | 20 | 110 | 1.3 | 0.035 | TO-3PF | 150 | 6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/84b7a8f9-225e-4fa4-9f65-ade88f2609cb?region=en-glb | LLD | Dual | 400 | 10 | 80 | 1.45 | 0.02 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/55e616fa-0c0a-4374-bd5d-71eac897fdec?region=en-glb | LLD | Dual | 400 | 10 | 80 | 1.45 | 0.02 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/377ff71d-6ade-489c-b4e3-f995fae90e4c?region=en-glb | LLD | Dual | 400 | 10 | 80 | 1.45 | 0.02 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6c76aa42-9b21-40af-8f65-ee2d755fa925?region=en-glb | LLD | Dual | 400 | 20 | 100 | 1.45 | 0.035 | TO-220F | 150 | 1.7 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5c9003f0-86f1-43af-be0e-bfe2e89c633c?region=en-glb | LLD | Dual | 400 | 20 | 100 | 1.45 | 0.035 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ffa45449-b192-4506-b835-2ea7cdc9f7cd?region=en-glb | LLD | Dual | 400 | 20 | 100 | 1.45 | 0.035 | T-Pack(S) | 150 | 1.6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4ca290b9-40df-4f91-962b-dc9d6782e15e?region=en-glb | LLD | Dual | 400 | 20 | 100 | 1.45 | 0.035 | TFP | 150 | 0.8 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9b7c200a-386c-45ee-bd9d-5410e319e527?region=en-glb | LLD | Dual | 400 | 20 | 100 | 1.45 | 0.035 | TO-3PF | 150 | 6 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/0d8e7e6c-03e4-44a1-ba3c-f1923d8f045a?region=en-glb | FRD | Single | 600 | 15 | 110 | 2.6 | 0.25 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/280b295c-afe3-4e64-aca3-fbc598d96021?region=en-glb | FRD | Single | 600 | 15 | 110 | 2.6 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/2e8881f0-410c-4d99-9e57-cff3c72c0aae?region=en-glb | FRD | Single | 600 | 25 | 125 | 2.6 | 0.25 | TO-220 | 150 | 2 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/ac93d0b0-0af9-4d3c-81c9-b24362271638?region=en-glb | FRD | Single | 600 | 25 | 125 | 2.6 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/99ac6168-280c-40c5-a838-cd3d66ee519b?region=en-glb | FRD | Single | 600 | 35 | 140 | 2.6 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
FRD | Single | 600 | 75 | 300 | 2.95 | 0.25 | TO-247-2(Type:A) | 150 | 4.9 | |||||||
FRD | Single | 650 | 60 | 250 | 3.2 | 0.25 | TO-247-2(Type:A) | 150 | 4.9 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/e97d5648-a690-4ce8-bc1d-fc145471fdc0?region=en-glb | FRD | Dual | 600 | 50 | 125 | 2.6 | 0.25 | TO-247(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/6d67208a-9bff-4982-b5b8-667c6883c9e2?region=en-glb | FRD | Dual | 600 | 70 | 140 | 2.6 | 0.25 | TO-247(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/8dc43182-e346-4e21-b2cf-cd933d1e8ba6?region=en-glb | FRD | Single | 1200 | 12 | 100 | 2.8 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/df6e4d00-90e9-412c-92de-0754e7ba7962?region=en-glb | FRD | Single | 1200 | 20 | 120 | 2.8 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a3c0f3c6-9264-4826-af48-f28b577fb696?region=en-glb | FRD | Single | 1200 | 30 | 150 | 2.8 | 0.25 | TO-247-2(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/a41323dc-10f8-4348-bd19-dffc56f8c552?region=en-glb | FRD | Dual | 1200 | 40 | 120 | 2.8 | 0.25 | TO-247(Type:B) | 150 | 4.9 | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/05a8125a-8148-4ef0-8f0e-7226b7fa9171?region=en-glb | FRD | Dual | 1200 | 60 | 150 | 2.8 | 0.25 | TO-247(Type:B) | 150 | 4.9 | ||||||
SiC-SBD | Single | 650 | 6 | 54 | 1.3 | 0.05 | TO-220-2 | 175 | 2 | |||||||
SiC-SBD | Single | 650 | 8 | 68 | 1.3 | 0.05 | TO-220-2 | 175 | 2 | |||||||
SiC-SBD | Single | 650 | 10 | 82 | 1.3 | 0.05 | TO-220-2 | 175 | 2 | |||||||
SiC-SBD | Single | 650 | 6 | 54 | 1.3 | 0.05 | TO-220F-2 | 175 | 1.7 | |||||||
SiC-SBD | Single | 650 | 8 | 68 | 1.3 | 0.05 | TO-220F-2 | 175 | 1.7 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/bb88e47c-97b9-488f-bca7-8c9538639576?region=en-glb | New | SiC-SBD | Single | 650 | 10 | 82 | 1.3 | 0.05 | TO-220F-2 | 175 | 1.7 | |||||
SiC-SBD | Single | 1200 | 20 | 145 | 1.57 | 0.01 | TO-247-2(Type:A) | 175 | 6 | |||||||
SiC-SBD | Single | 1200 | 40 | 290 | 1.57 | 0.01 | TO-247-2(Type:A) | 175 | 6 | |||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/9ce0838f-44de-4457-bd89-f6f19743e33e?region=en-glb | SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.01 | TO-220-2 | 175 | 2 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1bf8c38d-7323-4b46-93ab-9a282dbdbfbc?region=en-glb | SiC-SBD | Dual | 650 | 20 | 50 | 1.8 | 0.01 | TO-220 | 175 | 2 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/48266a2a-6631-446c-8cf0-b3d80eee18d0?region=en-glb | SiC-SBD | Single | 650 | 25 | 100 | 1.6 | 0.01 | TO-220-2 | 175 | 2 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/de1ede5c-61a2-4413-ab99-fdccc7ca1790?region=en-glb | SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.01 | TO-220F-2 | 175 | 1.7 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/1c251ee6-f4d1-4867-b67e-3bbae44d5845?region=en-glb | SiC-SBD | Dual | 650 | 20 | 50 | 1.8 | 0.01 | TO-220F | 175 | 1.7 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/d1f1c6f4-7305-4da8-b5d7-cf30a5999d06?region=en-glb | SiC-SBD | Single | 650 | 25 | 100 | 1.6 | 0.01 | TO-220F-2 | 175 | 1.7 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/49a31632-f3d4-458e-ab26-218be3bfdc66?region=en-glb | SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/c41ba272-68b2-412c-b77a-a3dbccca77ca?region=en-glb | SiC-SBD | Dual | 650 | 20 | 50 | 1.8 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/85bad47c-47fd-47ac-b654-4c4cd5c1e198?region=en-glb | SiC-SBD | Single | 650 | 25 | 100 | 1.6 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/7a38c1b1-8714-4d2e-8f24-0bb3be05d5ba?region=en-glb | SiC-SBD | Dual | 650 | 50 | 100 | 1.6 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.01 | T-Pack(S) | 175 | 1.6 | N | ||||||
SiC-SBD | Dual | 650 | 20 | 50 | 1.8 | 0.01 | T-Pack(S) | 175 | 1.6 | N | ||||||
SiC-SBD | Single | 650 | 25 | 100 | 1.6 | 0.01 | T-Pack(S) | 175 | 1.6 | N | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/4a7093fc-5149-48f0-8e89-4d074a97e8bd?region=en-glb | SiC-SBD | Single | 1200 | 18 | 90 | 1.7 | 0.01 | TO-220F-2 | 175 | 1.7 | N | |||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5aa3b0b4-f10b-457f-b889-2aff2d51d440?region=en-glb | SiC-SBD | Single | 1200 | 18 | 90 | 1.7 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
SiC-SBD | Single | 1200 | 18 | 90 | 1.7 | 0.01 | TO-247-2(Type:A) | 175 | 6 | N | ||||||
https://felib.fujielectric.co.jp/en/M10013/M20088/document_detail/5dc2de34-4a00-4de8-8d15-13353aeb9713?region=en-glb | SiC-SBD | Dual | 1200 | 36 | 90 | 1.7 | 0.01 | TO-247(Type:A) | 175 | 6.4 | N | |||||
SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.005 | TO-220-2 | 175 | 2 | Y | ||||||
SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.005 | TO-247(Type:A) | 175 | 6.4 | Y | ||||||
SiC-SBD | Single | 650 | 10 | 50 | 1.8 | 0.005 | T-Pack(S) | 175 | 1.6 | Y | ||||||
SiC-SBD | Dual | 650 | 20 | 100 | 1.8 | 0.005 | TO-220 | 175 | 2 | Y | ||||||
SiC-SBD | Dual | 650 | 20 | 100 | 1.8 | 0.005 | TO-247(Type:A) | 175 | 6.4 | Y | ||||||
SiC-SBD | Dual | 650 | 20 | 100 | 1.8 | 0.005 | T-Pack(S) | 175 | 1.6 | Y | ||||||
SiC-SBD | Single | 650 | 25 | 100 | 1.7 | 0.01 | TO-220-2 | 175 | 2 | Y | ||||||
SiC-SBD | Single | 650 | 25 | 100 | 1.7 | 0.01 | TO-247(Type:A) | 175 | 6.4 | Y | ||||||
SiC-SBD | Single | 650 | 25 | 100 | 1.7 | 0.01 | T-Pack(S) | 175 | 1.6 | Y | ||||||
SiC-SBD | Dual | 650 | 50 | 200 | 1.7 | 0.01 | TO-247(Type:A) | 175 | 6.4 | Y | ||||||
SiC-SBD | Single | 1200 | 18 | 90 | 1.8 | 0.01 | TO-247(Type:A) | 175 | 6.4 | Y | ||||||
SiC-SBD | Dual | 1200 | 36 | 180 | 1.8 | 0.01 | TO-247(Type:A) | 175 | 6.4 | Y |