Product Information

Product Information

Option/Peripheral Equipment

<Major example : 750W or less / 3000r/min>

■Basic option

Motor
series
Rated
speed
Brake Rated
output
1.
Sequence
I/O
cable
(between
host
and
amplifier)
2.
Power
supply
connector
3.
Motor
power
connector
(on
amplifier side)
4.
Motor
power
cable
(between
amplifier
and
motor
5.
Encoder
cable
(between
amplifier
and
motor)
6. Brake
cable
GYS motor 3000r/min Without brake 0.05kW to
0.75kW
WSC-
D36P03
WSK-
S05P-E
WSK-
M03P-E
(Excluding 2kW)
WSC-
M04P02-E
WSC-
M04P05-E
WSC-
M04P10-E
WSC-
M04P20-E
WSC-
P06P02-E
WSC-
P06P05-E
WSC-
P06P10-E
WSC-
P06P20-E
-
With brake WSC-
M02P02-E
WSC-
M02P05-E
WSC-
M02P10-E
WSC-
M02P20-E
Without brake 1.0kW to
2.0kW
*1 WSC-
P06P05-C
WSC-
P06P10-C
WSC-
P06P20-C
-
With brake *2 -
Without brake 3.0kW to
5.0kW
- - *3 -
With brake - - *4 -
GYC motor 3000r/min Without brake 0.05kW to
0.75kW
WSK-
S05P-E
WSK-
M03P-E
(Excluding 2kW)
WSC-
M04P02-E
WSC-
M04P05-E
WSC-
M04P10-E
WSC-
M04P20-E
WSC-
P06P02-E
WSC-
P06P05-E
WSC-
P06P10-E
WSC-
P06P20-E
-
With brake WSC-
M02P02-E
WSC-
M02P05-E
WSC-
M02P10-E
WSC-
M02P20-E
Without brake 1.0kW to
2.0kW
*3 WSC-P06P05-C
WSC-P06P10-C
WSC-P06P20-C
-
With brake *4 *No cable is required.
GYG motor 2000r/min Without brake 0.5kW to
1.0kW
WSK-
S05P-E
WSK-
M03P-E
*1 -
With brake *2 *No cable is required.
Without brake 1.5kW to
2.0kW
- - *1 -
With brake - - *2 *No cable is required.
1500r/min Without brake 0.5kW to
0.85kW
WSK-
S05P-E
WSK-
M03P-E
*1 -
With brake *2 *No cable is required.
Without brake 1.3kW - - *1 -
With brake - - *2 *No cable is required.
GYB motor 3000r/min Without brake 0.2kW, 0.4kW WSK-
M05P-E
WSK-
M03P-E
WSC-
M04P02-E
WSC-
M04P05-E
WSC-
M04P10-E
WSC-
M04P20-E
WSC-
P06P02-E
WSC-
P06P05-E
WSC-
P06P10-E
WSC-
P06P20-E
-
With brake WSC-
M02P02-E
WSC-
M02P05-E
WSC-
M02P10-E
WSC-
M02P20-E
Without brake 0.75kW WSK-
S03P-F
WSK-
M03P-F
-
With brake WSC-
M02P02-E
WSC-
M02P05-E
WSC-
M02P10-E
WSC-
M02P20-E

*1 The customer is requested to fabricate the cable using the connector for motor power (motor without brake): WSK-M04P-CA.
*2 The customer is requested to fabricate the cable using the connector for motor power (motor with brake): WSK-M06P-CA.
*3 The customer is requested to fabricate the cable using the connector for motor power (motor without brake): WSK-M04P-CB.
*4 The customer is requested to fabricate the cable using the connector for motor power (motor with brake): WSK-M06P-CB.

■Connector kit  * Use this connector if the customer fabricates the cable yourself.

Motor
series
Rated
speed
Brake Rated
output
A
Sequence
I/O
connector
B
Motor
power
connector
(on motor side)
Encoder
connector
E
Brake
connector
C
Amplifier side
D
Motor side
GYS motor
(0.05~5.0kW)
GYB motor
(0.2~0.75kW)
3000r/min Without brake 0.05kW to
0.75kW
WSK-
D36P
WSK-
M04P-E
WSK-
P06P-M
WSK-
P09P-D
-
With brake WSK-
M02P-E
Without brake 1.0kW to
1.5kW
WSK-
M04P-CA
WSK-
P06P-C
-
With brake WSK-
M06P-CA
-
Without brake 2.0kW WSK-
M04P-CA
-
With brake WSK-
M06P-CA
-
Without brake 3.0kW to 5.0kW WSK-
M04P-CB
-
With brake WSK-
M06P-CB
-
GYC motor 3000r/min Without brake 0.05kW to
0.75kW
WSK-
M04P-E
WSK-
P09P-D
-
With brake WSK-
M02P-E
Without brake 1.0kW to
1.5kW
WSK-
M04P-CB
WSK-
P06P-C
-
With brake WSK-
M06P-CB
Without brake 2.0kW WSK-
M04P-CB
With brake WSK-
M06P-CB
GYG motor 2000r/min Without brake 0.5kW to
1.0kW
WSK-
M04P-CA
With brake WSK-
M06P-CA
Without brake 1.5kW to
2.0kW
WSK-
M04P-CA
With brake WSK-
M06P-CA
1500r/min Without brake 0.5kW to
0.85kW
WSK-
M04P-CA
With brake WSK-
M06P-CA
Without brake 1.3kW WSK-
M04P-CA
With brake WSK-
M06P-CA

■Peripheral equipment

Rated
speed
Input
power
supply
Servo
amplifier
type
Output
of
applied motor
[kW]
Power
supply
capacity
[kVA]
Input
current
[A]
Power
filter
AC
reactor
DC
reactor
Molded
case
circuit
breaker
Ground
fault
interruptor
Electro-
magnetic
contactor
3000r/min Single-
phase
100V
RYT500D5-
□□6
0.05 0.1 1.5 RNFTC06-
20
ACR2-
0.4A
DCR2-
0.4
EA32
AC/3
EG32
AC/3
SC-03
RYT101D5-
□□6
0.1 0.2 2.6 ACR2-
0.75A
DCR2-
0.75
EA32
AC/5
EG32
AC/5
RYT201D5-
□□6
0.2 0.4 4.8 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
EA32
AC/10
EG32
AC/10
RYT401D5-
□□6
0.375 0.8 8.7 RNFTC20-
20
ACR2-
2.2A
DCR2-
2.2
EA32
AC/15
EG32
AC/15
SC-0
Single-
phase
200V
RYT500D5-
□□2
0.05 0.1 0.7 RNFTC06-
20
ACR2-
0.4A
DCR2-
0.2
EA32
AC/3
EG32
AC/3
SC-03
RYT101D5-
□□2
0.1 0.2 1.3 DCR2-
0.4
RYT201D5-
□□2
0.2 0.4 2.4 ACR2-
0.75A
DCR2-
0.75
EA32
AC/5
EG32
AC/5
RYT401D5-
□□2
0.4 0.8 4.7 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
EA32
AC/10
EG32
AC/10
RYT751D5-
□□2
0.75 1.5 8.6 RNFTC20-
20
ACR2-
2.2A
DCR2-
2.2
EA32
AC/15
EG32
AC/15
SC-0
3-phase
200V
RYT500D5-
□□2
0.05 0.1 0.4 RNFTC06-
20
ACR2-
0.4A
DCR2-
0.2
EA33
AC/3
EG33
AC/3
SC-03
RYT101D5-
□□2
0.1 0.2 0.7
RYT201D5-
□□2
0.2 0.4 1.4 DCR2-
0.4
RYT401D5-
□□2
0.4 0.8 2.7 ACR2-
0.75A
DCR2-
0.75
EA33
AC/5
EG33
AC/5
RYT751D5-
□□2
0.75 1.5 5.0 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
EA33
AC/10
EG33
AC/10
RYT102D5-
□□2
1.0 2.0 6.6 ACR2-
2.2A
DCR2-
2.2
EA33
AC/15

EG33
AC/15

RYT152D5-
□□2
1.5 2.9 9.8 RNFTC20-
20
EA33
AC/20
EG33
AC/20
SC-4-1
RYT202D5-
□□2
2.0 3.9 13.0 ACR2-
3.7A
DCR2-
3.7
EA33
AC/30
EG33
AC/30
SC-4-1
RYT302D5-
□□2
3.0 5.9 19.5 RNFTC30-
20
ACR2-
5.5A
DCR2-
5.5
EA53
AC/40
EG53
AC/40
SC-N1
RYT402D5-
□□2
4.0 7.8 26.0 RNFTC50-
20
ACR2-
7.5A
DCR2-
7.5
EA53
AC/50
EG53
AC/50
SC-N2
RYT502D5-
□□2
5.0 9.8 32.5 ACR2-
11A
DCR2-
11
EA53
AC/50
EG53
AC/50
2000r/min Single-
phase
200V
RYT501C5-
□□2
0.5 1.0 5.8 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
EA32
AC/10
EG32
AC/10
SC-03
RYT751C5-
□□2
0.75 1.5 8.6 RNFTC20-
20
ACR2-
2.2A
DCR2-
2.2
EA32
AC/15
EG32
AC/15
SC-0
3-phase
200V
RYT501C5-
□□2
0.5 1.0 3.3 RNFTC06-
20
ACR2-
0.75A
DCR2-
0.75
EA33
AC/10
EG33
AC/10
SC-03
RYT751C5-
□□2
0.75 1.5 5.0 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
RYT102C5-
□□2
1.0 2.0 6.6 ACR2-
2.2A
DCR2-
2.2
EA33
AC/15
EG33
AC/15
RYT152C5-
□□2
1.5 2.9 9.8 RNFTC20-
20
EA33
AC/20
EG33
AC/20
SC-4-1
RYT202C5-
□□2
2.0 3.9 13.0 ACR2-
3.7A
DCR2-
3.7
EA33
AC/30
EG33
AC/30
1500r/min Single-
phase
200V
RYT501B5-
□□2
0.5 1.0 5.8 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
EA32
AC/10
EG32
AC/10
SC-03
3-phase
200V
RYT501B5-
□□2
0.5 1.0 3.3 RNFTC06-
20
ACR2-
0.75A
DCR2-
0.75
EA33
AC/10
EG33
AC/10
SC-03
RYT851B5-
□□2
0.85 1.7 5.6 RNFTC10-
20
ACR2-
1.5A
DCR2-
1.5
RYT132B5-
□□2
1.3 2.6 8.5 RNFTC20-
20
ACR2-
2.2A
DCR2-
2.2
EA33
AC/15
EG33
AC/15
SC-0
Page Top