Product Information
Product Information
Option/Peripheral Equipment
<Major example : 750W or less / 3000r/min>
■Basic option
Motor series |
Rated speed |
Brake | Rated output |
1. Sequence I/O cable (between host and amplifier) |
2. Power supply connector |
3. Motor power connector (on amplifier side) |
4. Motor power cable (between amplifier and motor |
5. Encoder cable (between amplifier and motor) |
6. Brake cable |
---|---|---|---|---|---|---|---|---|---|
GYS motor | 3000r/min | Without brake | 0.05kW to 0.75kW |
WSC- D36P03 |
WSK- S05P-E |
WSK- M03P-E (Excluding 2kW) |
WSC- M04P02-E WSC- M04P05-E WSC- M04P10-E WSC- M04P20-E |
WSC- P06P02-E WSC- P06P05-E WSC- P06P10-E WSC- P06P20-E |
- |
With brake | WSC- M02P02-E WSC- M02P05-E WSC- M02P10-E WSC- M02P20-E |
||||||||
Without brake | 1.0kW to 2.0kW |
*1 | WSC- P06P05-C WSC- P06P10-C WSC- P06P20-C |
- | |||||
With brake | *2 | - | |||||||
Without brake | 3.0kW to 5.0kW |
- | - | *3 | - | ||||
With brake | - | - | *4 | - | |||||
GYC motor | 3000r/min | Without brake | 0.05kW to 0.75kW |
WSK- S05P-E |
WSK- M03P-E (Excluding 2kW) |
WSC- M04P02-E WSC- M04P05-E WSC- M04P10-E WSC- M04P20-E |
WSC- P06P02-E WSC- P06P05-E WSC- P06P10-E WSC- P06P20-E |
- | |
With brake | WSC- M02P02-E WSC- M02P05-E WSC- M02P10-E WSC- M02P20-E |
||||||||
Without brake | 1.0kW to 2.0kW |
*3 | WSC-P06P05-C WSC-P06P10-C WSC-P06P20-C |
- | |||||
With brake | *4 | *No cable is required. | |||||||
GYG motor | 2000r/min | Without brake | 0.5kW to 1.0kW |
WSK- S05P-E |
WSK- M03P-E |
*1 | - | ||
With brake | *2 | *No cable is required. | |||||||
Without brake | 1.5kW to 2.0kW |
- | - | *1 | - | ||||
With brake | - | - | *2 | *No cable is required. | |||||
1500r/min | Without brake | 0.5kW to 0.85kW |
WSK- S05P-E |
WSK- M03P-E |
*1 | - | |||
With brake | *2 | *No cable is required. | |||||||
Without brake | 1.3kW | - | - | *1 | - | ||||
With brake | - | - | *2 | *No cable is required. | |||||
GYB motor | 3000r/min | Without brake | 0.2kW, 0.4kW | WSK- M05P-E |
WSK- M03P-E |
WSC- M04P02-E WSC- M04P05-E WSC- M04P10-E WSC- M04P20-E |
WSC- P06P02-E WSC- P06P05-E WSC- P06P10-E WSC- P06P20-E |
- | |
With brake | WSC- M02P02-E WSC- M02P05-E WSC- M02P10-E WSC- M02P20-E |
||||||||
Without brake | 0.75kW | WSK- S03P-F |
WSK- M03P-F |
- | |||||
With brake | WSC- M02P02-E WSC- M02P05-E WSC- M02P10-E WSC- M02P20-E |
*1 The customer is requested to fabricate the cable using the connector for motor power (motor without brake): WSK-M04P-CA.
*2 The customer is requested to fabricate the cable using the connector for motor power (motor with brake): WSK-M06P-CA.
*3 The customer is requested to fabricate the cable using the connector for motor power (motor without brake): WSK-M04P-CB.
*4 The customer is requested to fabricate the cable using the connector for motor power (motor with brake): WSK-M06P-CB.
■Connector kit * Use this connector if the customer fabricates the cable yourself.
Motor series |
Rated speed |
Brake | Rated output |
A Sequence I/O connector |
B Motor power connector (on motor side) |
Encoder connector |
E Brake connector |
|
---|---|---|---|---|---|---|---|---|
C Amplifier side |
D Motor side |
|||||||
GYS motor (0.05ï½5.0kW) GYB motor (0.2ï½0.75kW) |
3000r/min | Without brake | 0.05kW to 0.75kW |
WSK- D36P |
WSK- M04P-E |
WSK- P06P-M |
WSK- P09P-D |
- |
With brake | WSK- M02P-E |
Without brake | 1.0kW to 1.5kW |
WSK- M04P-CA |
WSK- P06P-C |
- | ||
With brake | WSK- M06P-CA |
- | ||||||
Without brake | 2.0kW | WSK- M04P-CA |
- | |||||
With brake | WSK- M06P-CA |
- | ||||||
Without brake | 3.0kW to 5.0kW | WSK- M04P-CB |
- | |||||
With brake | WSK- M06P-CB |
- | ||||||
GYC motor | 3000r/min | Without brake | 0.05kW to 0.75kW |
WSK- M04P-E |
WSK- P09P-D |
- | ||
With brake | WSK- M02P-E |
Without brake | 1.0kW to 1.5kW |
WSK- M04P-CB |
WSK- P06P-C |
- | ||
With brake | WSK- M06P-CB |
|||||||
Without brake | 2.0kW | WSK- M04P-CB |
||||||
With brake | WSK- M06P-CB |
|||||||
GYG motor | 2000r/min | Without brake | 0.5kW to 1.0kW |
WSK- M04P-CA |
||||
With brake | WSK- M06P-CA |
|||||||
Without brake | 1.5kW to 2.0kW |
WSK- M04P-CA |
||||||
With brake | WSK- M06P-CA |
|||||||
1500r/min | Without brake | 0.5kW to 0.85kW |
WSK- M04P-CA |
|||||
With brake | WSK- M06P-CA |
Without brake | 1.3kW | WSK- M04P-CA |
||||
With brake | WSK- M06P-CA |
■Peripheral equipment
Rated speed |
Input power supply |
Servo amplifier type |
Output of applied motor [kW] |
Power supply capacity [kVA] |
Input current [A] |
Power filter |
AC reactor |
DC reactor |
Molded case circuit breaker |
Ground fault interruptor |
Electro- magnetic contactor |
---|---|---|---|---|---|---|---|---|---|---|---|
3000r/min | Single- phase 100V |
RYT500D5- □□6 |
0.05 | 0.1 | 1.5 | RNFTC06- 20 |
ACR2- 0.4A |
DCR2- 0.4 |
EA32 AC/3 |
EG32 AC/3 |
SC-03 |
RYT101D5- □□6 |
0.1 | 0.2 | 2.6 | ACR2- 0.75A |
DCR2- 0.75 |
EA32 AC/5 |
EG32 AC/5 |
||||
RYT201D5- □□6 |
0.2 | 0.4 | 4.8 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
EA32 AC/10 |
EG32 AC/10 |
|||
RYT401D5- □□6 |
0.375 | 0.8 | 8.7 | RNFTC20- 20 |
ACR2- 2.2A |
DCR2- 2.2 |
EA32 AC/15 |
EG32 AC/15 |
SC-0 | Single- phase 200V |
RYT500D5- □□2 |
0.05 | 0.1 | 0.7 | RNFTC06- 20 |
ACR2- 0.4A |
DCR2- 0.2 |
EA32 AC/3 |
EG32 AC/3 |
SC-03 |
RYT101D5- □□2 |
0.1 | 0.2 | 1.3 | DCR2- 0.4 |
|||||||
RYT201D5- □□2 |
0.2 | 0.4 | 2.4 | ACR2- 0.75A |
DCR2- 0.75 |
EA32 AC/5 |
EG32 AC/5 |
||||
RYT401D5- □□2 |
0.4 | 0.8 | 4.7 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
EA32 AC/10 |
EG32 AC/10 |
|||
RYT751D5- □□2 |
0.75 | 1.5 | 8.6 | RNFTC20- 20 |
ACR2- 2.2A |
DCR2- 2.2 |
EA32 AC/15 |
EG32 AC/15 |
SC-0 | ||
3-phase 200V |
RYT500D5- □□2 |
0.05 | 0.1 | 0.4 | RNFTC06- 20 |
ACR2- 0.4A |
DCR2- 0.2 |
EA33 AC/3 |
EG33 AC/3 |
SC-03 | |
RYT101D5- □□2 |
0.1 | 0.2 | 0.7 | ||||||||
RYT201D5- □□2 |
0.2 | 0.4 | 1.4 | DCR2- 0.4 |
|||||||
RYT401D5- □□2 |
0.4 | 0.8 | 2.7 | ACR2- 0.75A |
DCR2- 0.75 |
EA33 AC/5 |
EG33 AC/5 |
||||
RYT751D5- □□2 |
0.75 | 1.5 | 5.0 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
EA33 AC/10 |
EG33 AC/10 |
|||
RYT102D5- □□2 |
1.0 | 2.0 | 6.6 | ACR2- 2.2A |
DCR2- 2.2 |
EA33 AC/15 |
EG33 |
||||
RYT152D5- □□2 |
1.5 | 2.9 | 9.8 | RNFTC20- 20 |
EA33 AC/20 |
EG33 AC/20 |
SC-4-1 | ||||
RYT202D5- □□2 |
2.0 | 3.9 | 13.0 | ACR2- 3.7A |
DCR2- 3.7 |
EA33 AC/30 |
EG33 AC/30 |
SC-4-1 | |||
RYT302D5- □□2 |
3.0 | 5.9 | 19.5 | RNFTC30- 20 |
ACR2- 5.5A |
DCR2- 5.5 |
EA53 AC/40 |
EG53 AC/40 |
SC-N1 | ||
RYT402D5- □□2 |
4.0 | 7.8 | 26.0 | RNFTC50- 20 |
ACR2- 7.5A |
DCR2- 7.5 |
EA53 AC/50 |
EG53 AC/50 |
SC-N2 | ||
RYT502D5- □□2 |
5.0 | 9.8 | 32.5 | ACR2- 11A |
DCR2- 11 |
EA53 AC/50 |
EG53 AC/50 |
||||
2000r/min | Single- phase 200V |
RYT501C5- □□2 |
0.5 | 1.0 | 5.8 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
EA32 AC/10 |
EG32 AC/10 |
SC-03 |
RYT751C5- □□2 |
0.75 | 1.5 | 8.6 | RNFTC20- 20 |
ACR2- 2.2A |
DCR2- 2.2 |
EA32 AC/15 |
EG32 AC/15 |
SC-0 | ||
3-phase 200V |
RYT501C5- □□2 |
0.5 | 1.0 | 3.3 | RNFTC06- 20 |
ACR2- 0.75A |
DCR2- 0.75 |
EA33 AC/10 |
EG33 AC/10 |
SC-03 | |
RYT751C5- □□2 |
0.75 | 1.5 | 5.0 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
|||||
RYT102C5- □□2 |
1.0 | 2.0 | 6.6 | ACR2- 2.2A |
DCR2- 2.2 |
EA33 AC/15 |
EG33 AC/15 |
||||
RYT152C5- □□2 |
1.5 | 2.9 | 9.8 | RNFTC20- 20 |
EA33 AC/20 |
EG33 AC/20 |
SC-4-1 | ||||
RYT202C5- □□2 |
2.0 | 3.9 | 13.0 | ACR2- 3.7A |
DCR2- 3.7 |
EA33 AC/30 |
EG33 AC/30 |
||||
1500r/min | Single- phase 200V |
RYT501B5- □□2 |
0.5 | 1.0 | 5.8 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
EA32 AC/10 |
EG32 AC/10 |
SC-03 |
3-phase 200V |
RYT501B5- □□2 |
0.5 | 1.0 | 3.3 | RNFTC06- 20 |
ACR2- 0.75A |
DCR2- 0.75 |
EA33 AC/10 |
EG33 AC/10 |
SC-03 | |
RYT851B5- □□2 |
0.85 | 1.7 | 5.6 | RNFTC10- 20 |
ACR2- 1.5A |
DCR2- 1.5 |
|||||
RYT132B5- □□2 |
1.3 | 2.6 | 8.5 | RNFTC20- 20 |
ACR2- 2.2A |
DCR2- 2.2 |
EA33 AC/15 |
EG33 AC/15 |
SC-0 |