Synchronous Drive System
Inverters FRENIC-MEGA G2 Series
High Performance Multifunctional Inverters
FRENIC-MEGA (G2) Series !
FRENIC-MEGA (G2) Series !
High basic performance
-
Enables vector control with and without sensors
-
Improves current and speed response and enhances the speed control range
-
Comes with a built-in braking transistor with a capacity up to 75 kW
Various applications
-
Comes with a variety of functions suitable for different applications
(Improves automatic energy-saving operation, braking transistor damage detection, braking signals, etc.) -
Comes with customized logic functions
(260 programming steps) -
Compatible with network protocols
Easy maintenance
-
Improves work efficiency by simplifying wiring and setup
-
nhanced life cycle diagnosis and maintenance functions
(Cooling capacity reduction, IGBT life expectancy, main circuit capacitor, etc.) -
Achieves long main component life
Environmental resistance
-
Improves environmental performance
(Enhances operating ambient temperature by 55°C, improves PCB coating, etc.) -
Compliant with the revised European RoHS Directive
-
Conforms to overseas safety standards
Three-phase 200 V series
HHD spec High carrier frequency Heavy Duty(for heavy load)
HND spec High carrier frequency Normal Duty (for light load)
HHD spec High carrier frequency Heavy Duty(for heavy load)
HND spec High carrier frequency Normal Duty (for light load)
Three-phase 400 V series
HHD spec High carrier frequency Heavy Duty(for heavy load)
HND spec High carrier frequency Normal Duty (for light load)
HHD spec High carrier frequency Heavy Duty(for heavy load)
HND spec High carrier frequency Normal Duty (for light load)
-
*1
-
An applicable motor is one of our synchronous motor series (6P).
-
*2
-
Rated capacity is calculated by assuming the rated output voltage as 220 V for 200 V series and 440 V for 400 V series.
-
*3
-
Voltage unbalance(%) =Max. voltage (V) - Min. voltage (V) / Three-phase average voltage (V) ×67 (IEC 61800-3)
If this value is 2 to 3%, use an optional AC reactor (ACR).
-
*4
-
Required when a DC reactor (DCR) is used.
-
*5
-
When using a motor with a rating of 75 kW or more, be sure to use a DC reactor (option).