Device Level Communication Module
-
Programmable Controller PLC
- MICREX-SX SPH Series
- MICREX-SX SPF Series
-
Technical information
-
Catalog
- PLC Column
- Materials/Technical Inquiries
OPCN-1 Slave Module : NP1L-JS1
OPCN-1 Interface Module : NP1L-RJ1
NP1L-JP1
-
Up to eight units can be connected in a single system configuration.
-
Up to 31 slave stations can be connected to a single master unit.
-
Number of I/O points is a max. of 8192 points (512 words) For SPH200, up to 2048 points (128 words)
-
The transmission speed can be switched. (1 M/500 k/250 k/125 kbps)
NP1L-JS1
-
I/O data link through the OPCN-1 is possible between CPUs.
-
Number of I/O points is a max. of 2048 points (128 words)
NP1L-RJ1
-
Slave station configuration, conforming to the OPCN-1 Standard, implements compact, economical, centralized remote I/O as a multi-vendor network.
-
Input filtering time of the input module can be set with DIP switch on the front.
-
NP1L-JP1
-
NP1L-JS1
-
NP1L-RJ1
DeviceNet Slave Module : NP1L-DS1
DeviceNet Interface Module : NP1L-RD1
NP1L-DN1
-
1 Up to eight units can be connected in a single system configuration.
-
Up to 63 units of remote I/O equipment can be connected to a single master unit.
-
Number of I/O points is a max. of 8192 points (512 words) For SPH200, up to 2048 points (128 words)
-
The transmission speed can be switched. 125 kbps (500 m)/250 kbps (250 m)/500 kbps(100 m)
NP1L-DS1
-
I/O data link through the DeviceNet is possible between CPUs.
-
Number of I/O points is a max. of 2048 points (128 words)
NP1L-RD1
-
NP1L-RD1
-
NP1L-DN1
-
NP1L-DS1
-
NP1L-RD1
T-link slave module : NP1L-TS1
T-link Interface Module : NP1L-RT1
NP1L-TL1
-
1 Up to eight units can be connected in a single system configuration.
-
Up to 64 units of slave equipment can be connected to a single master unit.
-
Number of I/O points is a max. of 8192 points (512 words) For SPH200, up to 2048 points (128 words)
-
T-link equipment for such as MICREX-F and FLEX-PC can be used. (Some types excluded.)
NP1L-TS1
-
Data link by I/O data between CPUs through T-link is possible.
-
Five different numbers of I/O points (1 word/1 word, 2 words/2 words, 4 words/4 words, 8 words/8 words, 32 words/32 words) can be selected according to application.
NP1L-RT1
-
Realizes small, economic collective remote I/O as a T-link slave station.
-
NP1L-TL1
-
NP1L-TS1
-
NP1L-RT1
PROFIBUS-DP Slave Module : NP1L-PS1
PROFIBUS-DP Interface Module : NP1L-RP1
NP1L-PD2
-
Open system
Diverse slave products of PROFIBUS-DP can be connected. As for the DP slave, the compatibility authenticated by the PROFIBUS association has been confirmed. (The number of vendors exceeds 300.) -
Flexible system configuration
In addition to the basic configuration consisting of one DP master and multiple DP slaves, combinations with multiple DP masters and multiple DP slaves are possible, making it easier to distribute master functions. Max. number of unit connections (including master stations) is 126. With 33 units or more, repeaters are required. -
Transmission speed
Can be selected from nine options: 9.6/19.2/93.75/187.5/500/1500/ 3000/6000/12000 kbps. (The upper limit depends on the type of the DP slave.)
NP1L-PR1
-
This Computer Level Communication Module realizes collective remote I/O as a PROFIBUS-DP slave station.
NP1L-PS1
-
I/O data link through the PROFIBUS-DP is possible between CPUs.
-
A max. of 128 words can be controlled as an input/output total of I/O points.
-
NP1L-PD2
-
NP1L-PS1
-
NP1L-PR1
NP1L-MN1
-
The module is available as a master or slave station by switching the station No.
-
Up to seven child stations can be connected.
-
A terminating resistor is built-in.
-
NP1L-MN1
Compatible with diverse device level networks
Device level network which performs high-speed communication of I/O information and messages between a programmable controller, a personal computer, and other controllers and an inverter, a servo, and MMI device, and other FA devices, among diverse networks consisting of an FA system, ranging from the computer level to the bit level. The I/O terminal corresponds to open device level networks (OPCN-1, DeviceNet, LONWORKS) and Fuji Electric's original networks (T-link, SX bus).
Easy maintenance
Since removable terminal blocks are used as the terminal blocks for the communication section, power supply, and I/O, the main unit can be attached and removed easily.
Preventing mis-wiring
Uses different colors for the surface sheets of the main unit: input (white), output (black), and I/O mixture (zebra). Applicable networks are also displayed, enabling the unit type to be determined at a glance.
Enabling DIN rail attachment
Not only usual screw attachment but also DIN rail attachment is possible.
-
NR1 series
-
NR2 series