Specifications of Servo Amplifier
Specifications of Servo Amplifier
Interface specifications
Terminal name | Pin Symbol | Specifications |
---|---|---|
Pulse train input | CA , *CA , CB , *CB | Differential input:max. input frequency ≤ 500kHz, (1) Command pulse/command code, (2) Forward rotation pulse/reverse rotation pulse, (3) two signals at 90-degree phase difference |
Divided output *6 | FA , *FA , FB , *FB , FZ ,*FZ | Differential output:max. output frequency ≤ 500kHz, two signals at 90-degree phase difference, 16 to 16384 [pulses/rev] |
Power output for analog input | P10 | +10V±0.4V (maximum output current 30mA) |
Speed command input | NREF | ±10V (Input impedance 20kΩ) |
Torque command input (V type only) |
TREF | ±10V (Input impedance 20kΩ) |
Monitor output 1,monitor output 2 *7 | MON1 , MON2 | Output for analog meter (both-side amplitude/single-side amplitude), (1) Speed command, (2) Speed return, (3) Torque command, (4) Position deviation |
Power input for sequence signals | P24 , M24 | External power supply of 24V DC/300mA required. |
Sequence input signal |
V type :CONT1 to CONT8 L/R type :CONT1 to CONT21 |
24V DC/10mA (1-point) Can be assigned to each function through parameter setup. |
Sequence output signal |
V type :OUT1 to OUT5 R type :OUT1 to OUT10 |
30V DC/50mA (1-point) Can be assigned to each function through parameter setup. |
External backup | BAT + , BAT - | Input pin for supplying backup power externally. |
*6) | The RS-485 and T-link types are output via open collector, and maximum output frequency is 200kHz. |
*7) | MON2 only for RS-485 and T-link types. |