Specifications of Servo Amplifier

Specifications of Servo Amplifier

Basic specifications

Applicable motor rated speed 3000r/min 3000r/min 1500r/min
(low base)
1500r/min
(medium capacity
type α )
Applicable motor output [kW] 0.05 0.1 0.2 0.375 0.05 0.1 0.2 0.4 0.75 1.0 1.5 2.0 3.0 4.0 5.0 0.5 1.5 2.5 2.9 4.0 5.5 7.5 11 15
Amplifier
type
*1
RYS***S3
-△△△□
500 101 201 371 500 101 201 401 751 102 152 202 302 402 502
RYS***A3
-VVX or VVS
501 152 252
RYS***M6
-△△△
292 402 552 752 113 153
Mass [kg] 0.9 1.2 1.5 0.9 1.2 1.5 2.0 4.6 4.7 5.2 1.5 2.0 4.7 5.2 8.5 25
Input Phase Single-phase 3-phase (Single-phase input allowed for 200W or less only)
Voltage AC100 to 115V,
-15 to +10%
200 to 230V, -15 to +10% 200 to 230V*2, -15 to +10%
Frequency 50/60Hz
Control input voltage Single-phase:100 to 115V AC,
-15 to +10%
Single-phase:200 to 230V AC, -15 to +10%
Output Control method IGBT sinusoidal PWM drive
Overload
resistance
3〔s〕 300% 300% 242% 250% 236%
1.5〔s〕*3 450%
Control method Regenerative braking for DC link circuit
Feedback 16-bit serial encoder (ABS/INC)
Capability and function Max speed 5000r/min 2500r/min 3000r/min 2000r/min
Speed control range *4 1:5000 1:3000
Frequency response *5 600Hz 300Hz
Speed fluctuation ratio Within ±1[r/min] :load fluctuation (0 to 100%), power fluctuation (-10% to +10%)
Within ±0.2% :temperature fluctuation (25℃±10℃ at rated rotation speed and analog input operation)
Resolution 216(=65536)/1 rotation
V type control function Common Speed
control
Manual operation (analog voltage, multi-stage 7-speed)
Position
control
Manual operation (analog voltage, multi-stage 7-speed, interrupt positioning), pulse train (pulse train magnification 1, pulse train magnification 2)
Torque
control
Manual operation (analog voltage)
Position
management
INC/ABS selectable. When ABS is selected, a battery is mounted on the amplifier.
INC: Current position lost when power is turned off. No rotation limitation ABS: Current position restored upon power recovery. Rotation limitation provided (rotation range: 32767 rotations)
VVS,
VSS,
VVK,
VSK
unique
function
Home
setup
Home position LS and Z phase, position presetting, homing (4 patterns)
Accessory
functions
Override, brake timing, speed command auxiliary input, etc.
L type
control
function
Position
control
Automatic start (address designation, sequential start, immediate start), manual operation (analog voltage, multi-stage 7-speed, interrupt positioning), pulse train (pulse train magnification 1, pulse train magnification 2), homing (4 patterns)
Position
management
INC/ABS selectable. When ABS is selected, a battery is mounted on the amplifier.
INC: Current position lost when power is turned off. No rotation limitation ABS: Current position regenerated upon power recovery. Rotation limitation provided (rotation range: 32767 rotations)
Home
setup
Home position LS and Z phase, position presetting
Position
data count
99 points (position, speed, timer, M code, and various statuses)
Max position
setup
±79,999,999 (×Unit value)
Positioning
method
Absolute/incremental
Accessory
function
Override, brake timing, etc.
R type
control
function
Position
control
Automatic start (station designation), manual operation (analog voltage, multi-stage 3-speed, manual indexing), pulse train (pulse train magnification 1, pulse train magnification 2), homing
Position
management
INC/ABS selectable. When ABS is selected, a battery is mounted on the amplifier.
INC: Current position lost when power is tunred off. No rotation limitation ABS: Current position regenerated upon power recovery. No rotation limitation.
Home
setup
Home position LS and Z phase, position presetting
Max division
count
7999 (BCD setup)/30000 (Binary setup)
Deceleration
ratio
1/9999 to 1/1
Positioning
method
Shortcut/forward rotation/reverse rotation, absolute/incremental
Accessory
functions
Override, brake timing, second home position, etc.
Protective function
(Alarm indication)
Overcurrent (OC), Overspeed (OS), Undervoltage (Lv), Overvoltage (Hv), Encoder error (Et), Control power error (Ct), Memory error (dE), Combination error (CE),
Regenerative transistor overheat (rH2), Encoder communication error (EC), CONT overlapping (CtE), Overload (OL), Regenerative resistor overheat (rH),
Deviation overflow (OF), Amplifier overheat (AH), Encoder overheat (EH), Multi-rotation data loss (AL), Multi-rotation overflow (AF)
Note: "Combination error (CE)" and "Regenerative resistor overheat (rH)" are not supported with the medium capacity type FALDIC-α (model of 1500r/min, 2.9kW or above).
Note: "Encoder overheat (EH)" is not supported with the medium capacity type FALDIC-α (model of 1500r/min, 2.9kW or above) during incremental drive of the motor.
Applicable
environment
Installation place Indoors (free from direct sunshine), altitude ≤ 1000m, free from corrosive and flammable gases, oil mist and dust
In case of compliance with CE marking
Models compliant with EU directive: pollution degree 2, over voltage categoryⅡ
Temperature/humidity -10 to 55℃/10 to 90%RH (without condensation)
Vibration/shock resistance 4.9m/s2/19.6m/s2
Standards UL/cUL (UL508c), CE marking (low voltage directive EN50178)
*1) △represents an alphabet depending on the amplifier type (VVX,VVS,VSS,VVK,VSK,LPS,LSS,LTS,LRS,LPK,LSK,RPS,RSS,RTS)
□represents "6" or "no mark" depending on the input power type ("6" = single-phase 100V input, "no mark" = 3-phase 200V input)
*2) The specifications of 220 to 230V/50Hz with motor output 5.5 to 15kW are available as option.
*3) The following types can only support 1.5 [s] overload rating (450%): "VVS" "VSS" "LPS" "LSS" "LTS" "LRS" "RPS" "RSS" "RTS"
*4) The minimum rotation speed is the speed that does not result in stop at the rated load.
*5) Motor shaft converted load inertia moment (JL) = Motor inertia moment (JM): 100% load