Standard Specifications Single-phas 200V
-
-
-
Basic type / Finless type(Single-phase 200V)
Item |
Specifications |
Type ( FRN□□□E3S-7J
(Basic type) ) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
Type ( FRN□□□E3T-7J
(Finless type) ) |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
Type ( FRN□□□E3S-7J
(Basic type) ) |
HND |
0.1 |
0.2 |
0.4
(Note10) |
0.75
(Note10) |
1.5
(Note10) |
2.2
(Note10) |
Type ( FRN□□□E3T-7J
(Finless type) ) |
0.1 |
0.2 |
0.4
(Note10) |
0.75
(Note10) |
1.5
(Note10) |
2.2
(Note10) |
Nominal applied motor [kW (HP)] (Note1) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.2 |
0.4 |
0.55 |
1.1 |
2.2(Note8) |
3(Note9) |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.2 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 (with AVR function) |
Rated current [A] (Note4) |
HHD |
1.0 |
1.6 |
3.0 |
5.0 |
8.0 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6.0 |
9.6 |
12 |
Overload capacity |
HHD |
150%-1min,200%-0.5s |
HND |
120%-1min |
Ambient temperature |
Basic type |
HHD |
-10 to +55℃(current derating necessary in+50 to +55℃) |
Finless type |
-10 to +50℃(current derating necessary in+35 to +50℃) |
Basic type |
HND |
-10 to +55℃(current derating necessary in+50~+55℃)、FRN2.2/3.7E3□-2J -10 to +50℃(current derating necessary in+40 to +50℃) |
Rated frequency [Hz] |
50, 60 |
Input ratings |
Main circuit power: Phases, voltage, frequency |
Three-phase 200 to 240V, 50/60Hz |
Voltage, frequency variations |
Voltage:(+10 to -10% Frequency:+5 to -5% |
Rated current [A] (Note5) |
with DCR |
HHD |
1.1 |
2.0 |
3.5 |
6.4 |
11.6 |
17.5 |
without DCR |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
with DCR |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
without DCR |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity [kVA] (Note6) |
with DCR |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
with DCR |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Braking |
Torque [%] (Note7) |
HHD |
150 |
100 |
70 |
40 |
HND |
75 |
73 |
68 |
48 |
29 |
Braking transistor |
Built-in as standard |
Ohmic value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor |
Option |
DC injection braking |
HHD |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% |
HND |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
DC reactor (DCR) |
Option |
Applicable safety standards (Planned) |
UL61800-5-1,C22.2 No.274-17,IEC/EN 61800-5-1,EN ISO 13849-1 Cat.3/PL:e,
EN 60204-1 stop category 0, EN 61800-5-2 SIL3(Functional Safety:STO),EN 62061 SIL3, SEMI F47-0706 |
Enclosure (IEC60529) |
IP20 closed type, UL open type |
Cooling method |
Basic type |
Natural cooling |
Fan cooling |
Finless type |
No cooling |
Weight/Mass [kg (lb)] |
Basic type |
0.5 |
0.5 |
0.6 |
0.9 |
1.4 |
1.7 |
Finless type |
0.6 |
0.6 |
0.6 |
0.7 |
1.2 |
1.5 |
-
Note1
-
Fuji's 4-pole standard motor When selecting an inverter, in addition to considering the kWs of the inverter, make sure that the output current rating is larger than the motor current rating.
-
Note2
-
The rated capacity is for 200V series: 220V rating.
-
Note3
-
Output voltage cannot exceed the power supply voltage.
-
Note4
-
If the carrier frequency (function code F26) is set to a value higher than the value shown below, it must be reduced.
HHD : 8kHz
HND : 4kHz
-
Note5
-
These values are calculated on assumption that the inverter is connected to a power supply with a capacity of 500 kVA (or 10 times the inverter capacity when the inverter capacity exceeds 50 kVA) and %X is 5%.
-
Note6
-
Required when a DC reactor (DCR) is used.
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.0 kW.
-
Note9
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.7 kW.
-
Note10
-
Set F80=4. However, for capacities of 0.4 kW or more, if the ambient temperature is 40°C or higher, the rated current must be reduced by 2%/°C.
Ethernet built-in type(Single-phase 200V)
Item |
Specifications |
Type(FRN□□□E3N-7J) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.1 |
0.2 |
0.4
(Note10) |
0.75
(Note10) |
1.5
(Note10) |
2.2
(Note10) |
Nominal applied motor [kW (HP)] (Note1) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.2 |
0.4 |
0.55 |
1.1 |
2.2(Note8) |
3(Note9) |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.2 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 (with AVR function) |
Rated current [A] (Note4) |
HHD |
1.0 |
1.6 |
3.0 |
5.0 |
8.0 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6.0 |
9.6 |
12 |
Overload capacity |
HHD |
150%-1min,200%-0.5s |
HND |
120%-1min |
Ambient temperature |
HHD |
-10 to +55℃(current derating necessary in+50 to +55℃) |
HND |
-10 to +55℃(current derating necessary in+50 to +55℃)
FRN2.2/3.7E3□-4J -10 to +50℃(current derating necessary in+40 to +50℃) |
Rated frequency [Hz] |
50, 60 |
Input ratings |
Main circuit power: Phases, voltage, frequency |
Three-phase 200 to 240V, 50/60Hz |
Voltage, frequency variations |
Voltage:(10 to -15% Frequency:+5 to -5% |
Rated current [A] (Note5) |
with DCR |
HHD |
1.1 |
2.0 |
3.5 |
6.4 |
11.6 |
17.5 |
without DCR |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Rated current [A] (Note5) |
with DCR |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
without DCR |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity [kVA] (Note6) |
with DCR |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Braking |
Torque [%] (Note7) |
HHD |
150 |
100 |
70 |
40 |
HND |
75 |
73 |
68 |
48 |
29 |
Braking transistor |
Built-in as standard |
Ohmic value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor |
Option |
DC injection braking |
HHD |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% |
HND |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
DC reactor (DCR) |
Option |
Applicable safety standards (Planned) |
UL61800-5-1,C22.2 No.274-17,IEC/EN 61800-5-1,EN ISO 13849-1 Cat.3/PL:e,
EN 60204-1 stop category 0, EN 61800-5-2 SIL3(Functional Safety:STO),EN 62061 SIL3, SEMI F47-0706 |
Enclosure (IEC60529) |
IP20 closed type, UL open type |
Cooling method |
Natural cooling |
Fan cooling |
Weight/Mass [kg (lb)] |
0.5 |
0.5 |
0.7 |
0.9 |
1.5 |
1.7 |
-
Note1
-
Fuji's 4-pole standard motor When selecting an inverter, in addition to considering the kWs of the inverter, make sure that the output current rating is larger than the motor current rating.
-
Note2
-
The rated capacity is for 200V series: 220V rating.
-
Note3
-
Output voltage cannot exceed the power supply voltage.
-
Note4
-
If the carrier frequency (function code F26) is set to a value higher than the value shown below, it must be reduced.
HHD : 8kHz
HND : 4kHz
-
Note5
-
These values are calculated on assumption that the inverter is connected to a power supply with a capacity of 500 kVA (or 10 times the inverter capacity when the inverter capacity exceeds 50 kVA) and %X is 5%.
-
Note6
-
Required when a DC reactor (DCR) is used.
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.0 kW.
-
Note9
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.7 kW.
-
Note10
-
Set F80=4. However, for capacities of 0.4 kW or more, if the ambient temperature is 40°C or higher, the rated current must be reduced by 2%/°C.
-
Standard Specifications Single-phas 200V
-
-
-
Basic type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3S-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
|
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.6
[1.3] |
0.9
[2.0] |
1.4
[3.1] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
Ethernet built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3N-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.7
[1.5] |
0.9
[2.0] |
1.5
[3.3] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
EMC filter built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3E-7G) |
0001 |
0002 |
0003 |
0005 |
0008 |
0011 |
Standard applicable motor (Note 1)HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
Output ratings |
Rated capacity [kVA] (Note 2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
Rated voltage [V] (Note 3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note 4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) ,
Frequency: +5 to -5 % |
Rated current [A] (Note 5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Required power supply capacity (with DCR) [kVA] (Note 6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
Auxiliary control power supply voltage |
– |
|
Braking |
Torque (Note 7) |
HHD |
150% |
100% |
70% |
40% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
EMC filter(E3E) |
Compliant with EMC Directives.
Emission: Category C2.
Immunity: 2nd Env. (EN61800-3) |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.6
[1.3] |
0.6
[1.3] |
0.8
[1.8] |
1.2
[2.6] |
2.0
[4.4] |
2.2
[4.9] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
EMC filter built-in type is only available in HHD specification.
-
Standard Specifications Single-phas 200V
-
-
-
Basic type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3S-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
|
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.6
[1.3] |
0.9
[2.0] |
1.4
[3.1] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
Ethernet built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3N-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.7
[1.5] |
0.9
[2.0] |
1.5
[3.3] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
EMC filter built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3E-7G) |
0001 |
0002 |
0003 |
0005 |
0008 |
0011 |
Standard applicable motor (Note 1)HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
Output ratings |
Rated capacity [kVA] (Note 2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
Rated voltage [V] (Note 3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note 4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) ,
Frequency: +5 to -5 % |
Rated current [A] (Note 5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Required power supply capacity (with DCR) [kVA] (Note 6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
Auxiliary control power supply voltage |
– |
|
Braking |
Torque (Note 7) |
HHD |
150% |
100% |
70% |
40% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
EMC filter(E3E) |
Compliant with EMC Directives.
Emission: Category C2.
Immunity: 2nd Env. (EN61800-3) |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.6
[1.3] |
0.6
[1.3] |
0.8
[1.8] |
1.2
[2.6] |
2.0
[4.4] |
2.2
[4.9] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
EMC filter built-in type is only available in HHD specification.
-
Standard Specifications Single-phas 200V
-
-
This type is not available in this region.
If you need more information for this products, please contact us through the inquiry form.
-
Standard Specifications Single-phas 200V
-
-
-
Basic type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3S-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
|
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.6
[1.3] |
0.9
[2.0] |
1.4
[3.1] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
Ethernet built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3N-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.7
[1.5] |
0.9
[2.0] |
1.5
[3.3] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
EMC filter built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3E-7G) |
0001 |
0002 |
0003 |
0005 |
0008 |
0011 |
Standard applicable motor (Note 1)HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
Output ratings |
Rated capacity [kVA] (Note 2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
Rated voltage [V] (Note 3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note 4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) ,
Frequency: +5 to -5 % |
Rated current [A] (Note 5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Required power supply capacity (with DCR) [kVA] (Note 6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
Auxiliary control power supply voltage |
– |
|
Braking |
Torque (Note 7) |
HHD |
150% |
100% |
70% |
40% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
EMC filter(E3E) |
Compliant with EMC Directives.
Emission: Category C2.
Immunity: 2nd Env. (EN61800-3) |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.6
[1.3] |
0.6
[1.3] |
0.8
[1.8] |
1.2
[2.6] |
2.0
[4.4] |
2.2
[4.9] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
EMC filter built-in type is only available in HHD specification.
-
Standard Specifications Single-phas 200V
-
-
-
Basic type(Single-phase 200V)
Item |
Specifications |
Type ( FRN□□□E3S-7J ) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.1 |
0.2 |
0.4
(Note10) |
0.75
(Note10) |
1.5
(Note10) |
2.2
(Note10) |
Nominal applied motor [kW (HP)] (Note1) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.2 |
0.4 |
0.55 |
1.1 |
2.2(Note8) |
3(Note9) |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.2 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 (with AVR function) |
Rated current [A] (Note4) |
HHD |
1.0 |
1.6 |
3.0 |
5.0 |
8.0 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6.0 |
9.6 |
12 |
Overload capacity |
HHD |
150%-1min,200%-0.5s |
HND |
120%-1min |
Ambient temperature |
Basic type |
HHD |
-10 to +55℃(current derating necessary in+50 to +55℃) |
Basic type |
HND |
-10 to +55℃(current derating necessary in+50~+55℃)、FRN2.2/3.7E3□-2J -10 to +50℃(current derating necessary in+40 to +50℃) |
Rated frequency [Hz] |
50, 60 |
Input ratings |
Main circuit power: Phases, voltage, frequency |
Three-phase 200 to 240V, 50/60Hz |
Voltage, frequency variations |
Voltage:(+10 to -10% Frequency:+5 to -5% |
Rated current [A] (Note5) |
with DCR |
HHD |
1.1 |
2.0 |
3.5 |
6.4 |
11.6 |
17.5 |
without DCR |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
with DCR |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
without DCR |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity [kVA] (Note6) |
with DCR |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
with DCR |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Braking |
Torque [%] (Note7) |
HHD |
150 |
100 |
70 |
40 |
HND |
75 |
73 |
68 |
48 |
29 |
Braking transistor |
Built-in as standard |
Ohmic value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor |
Option |
DC injection braking |
HHD |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% |
HND |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
DC reactor (DCR) |
Option |
Applicable safety standards (Planned) |
UL61800-5-1,C22.2 No.274-17,IEC/EN 61800-5-1,EN ISO 13849-1 Cat.3/PL:e,
EN 60204-1 stop category 0, EN 61800-5-2 SIL3(Functional Safety:STO),EN 62061 SIL3, SEMI F47-0706 |
Enclosure (IEC60529) |
IP20 closed type, UL open type |
Cooling method |
Natural cooling |
Fan cooling |
Weight/Mass [kg (lb)] |
0.5 |
0.5 |
0.6 |
0.9 |
1.4 |
1.7 |
-
Note1
-
Fuji's 4-pole standard motor When selecting an inverter, in addition to considering the kWs of the inverter, make sure that the output current rating is larger than the motor current rating.
-
Note2
-
The rated capacity is for 200V series: 220V rating.
-
Note3
-
Output voltage cannot exceed the power supply voltage.
-
Note4
-
If the carrier frequency (function code F26) is set to a value higher than the value shown below, it must be reduced.
HHD : 8kHz
HND : 4kHz
-
Note5
-
These values are calculated on assumption that the inverter is connected to a power supply with a capacity of 500 kVA (or 10 times the inverter capacity when the inverter capacity exceeds 50 kVA) and %X is 5%.
-
Note6
-
Required when a DC reactor (DCR) is used.
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.0 kW.
-
Note9
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.7 kW.
-
Note10
-
Set F80=4. However, for capacities of 0.4 kW or more, if the ambient temperature is 40°C or higher, the rated current must be reduced by 2%/°C.
Ethernet built-in type(Single-phase 200V)
Item |
Specifications |
Type(FRN□□□E3N-7J) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.1 |
0.2 |
0.4
(Note10) |
0.75
(Note10) |
1.5
(Note10) |
2.2
(Note10) |
Nominal applied motor [kW (HP)] (Note1) |
HHD |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HND |
0.2 |
0.4 |
0.55 |
1.1 |
2.2(Note8) |
3(Note9) |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.2 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 (with AVR function) |
Rated current [A] (Note4) |
HHD |
1.0 |
1.6 |
3.0 |
5.0 |
8.0 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6.0 |
9.6 |
12 |
Overload capacity |
HHD |
150%-1min,200%-0.5s |
HND |
120%-1min |
Ambient temperature |
HHD |
-10 to +55℃(current derating necessary in+50 to +55℃) |
HND |
-10 to +55℃(current derating necessary in+50 to +55℃)
FRN2.2/3.7E3□-4J -10 to +50℃(current derating necessary in+40 to +50℃) |
Rated frequency [Hz] |
50, 60 |
Input ratings |
Main circuit power: Phases, voltage, frequency |
Three-phase 200 to 240V, 50/60Hz |
Voltage, frequency variations |
Voltage:(10 to -15% Frequency:+5 to -5% |
Rated current [A] (Note5) |
with DCR |
HHD |
1.1 |
2.0 |
3.5 |
6.4 |
11.6 |
17.5 |
without DCR |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Rated current [A] (Note5) |
with DCR |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
without DCR |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity [kVA] (Note6) |
with DCR |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Braking |
Torque [%] (Note7) |
HHD |
150 |
100 |
70 |
40 |
HND |
75 |
73 |
68 |
48 |
29 |
Braking transistor |
Built-in as standard |
Ohmic value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor |
Option |
DC injection braking |
HHD |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100% |
HND |
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% |
DC reactor (DCR) |
Option |
Applicable safety standards (Planned) |
UL61800-5-1,C22.2 No.274-17,IEC/EN 61800-5-1,EN ISO 13849-1 Cat.3/PL:e,
EN 60204-1 stop category 0, EN 61800-5-2 SIL3(Functional Safety:STO),EN 62061 SIL3, SEMI F47-0706 |
Enclosure (IEC60529) |
IP20 closed type, UL open type |
Cooling method |
Natural cooling |
Fan cooling |
Weight/Mass [kg (lb)] |
0.5 |
0.5 |
0.7 |
0.9 |
1.5 |
1.7 |
-
Note1
-
Fuji's 4-pole standard motor When selecting an inverter, in addition to considering the kWs of the inverter, make sure that the output current rating is larger than the motor current rating.
-
Note2
-
The rated capacity is for 200V series: 220V rating.
-
Note3
-
Output voltage cannot exceed the power supply voltage.
-
Note4
-
If the carrier frequency (function code F26) is set to a value higher than the value shown below, it must be reduced.
HHD : 8kHz
HND : 4kHz
-
Note5
-
These values are calculated on assumption that the inverter is connected to a power supply with a capacity of 500 kVA (or 10 times the inverter capacity when the inverter capacity exceeds 50 kVA) and %X is 5%.
-
Note6
-
Required when a DC reactor (DCR) is used.
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.0 kW.
-
Note9
-
If the power supply voltage is less than 220 V, the standard applicable motor is 2.7 kW.
-
Note10
-
Set F80=4. However, for capacities of 0.4 kW or more, if the ambient temperature is 40°C or higher, the rated current must be reduced by 2%/°C.
-
Standard Specifications Single-phas 200V
-
-
-
Basic type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3S-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
|
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.6
[1.3] |
0.9
[2.0] |
1.4
[3.1] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
Ethernet built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3N-7G)(Note10) |
0001 |
0002 |
0004
(Note11) |
0006
(Note11) |
0010
(Note11) |
0012
(Note11) |
Standard applicable motor (Note1) |
HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
HND |
kW |
0.2 |
0.4 |
0.55 |
1.1 |
2.2
(Note8) |
3
(Note9) |
HP |
1/4 |
1/2 |
3/4 |
1.5 |
3 |
4 |
Output ratings |
Rated capacity [kVA] (Note2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
HND |
0.5 |
0.7 |
1.3 |
2.3 |
3.7 |
4.6 |
Rated voltage [V] (Note3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
HND |
1.2 |
1.9 |
3.5 |
6 |
9.6 |
12 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
HND |
120% for 1 minute |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
HND |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range)
Type of 0004 to 0012 -10 to +50 ºC [14 to 122 ºF]
(current derating necessary in +40 to +50 ºC [104 to 122 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) , Frequency: +5 to -5 % |
Rated current [A] (Note5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
HND |
2.2 |
3.7 |
4.6 |
9.4 |
17.9 |
25 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
HND |
3.3 |
4.9 |
7.3 |
13.8 |
20.2 |
26 |
Required power supply capacity (with DCR) [kVA] (Note6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
HND |
0.5 |
0.8 |
1.0 |
1.9 |
3.6 |
5.0 |
Auxiliary control power supply voltage |
– |
Braking |
Torque (Note7) |
HHD |
150% |
100% |
70% |
40% |
HND |
75% |
73% |
68% |
48% |
29% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.5
[1.1] |
0.5
[1.1] |
0.7
[1.5] |
0.9
[2.0] |
1.5
[3.3] |
1.7
[3.7] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
For FRN0004E3S-7G to FRN0012E3S-7G, FRN0004E3N-7G to FRN0012E3N-7G HND specifications. If the ambient temperature is 40ºC or higher, the output
current must be derated by 2%/ºC.
EMC filter built-in type(Single-phase 200V)
Item |
Specification |
Type(FRN□□□□E3E-7G) |
0001 |
0002 |
0003 |
0005 |
0008 |
0011 |
Standard applicable motor (Note 1)HHD |
kW |
0.1 |
0.2 |
0.4 |
0.75 |
1.5 |
2.2 |
HP |
1/8 |
1/4 |
1/2 |
1 |
2 |
3 |
Output ratings |
Rated capacity [kVA] (Note 2) |
HHD |
0.4 |
0.6 |
1.1 |
1.9 |
3.0 |
4.2 |
Rated voltage [V] (Note 3) |
Three-phase 200 to 240 V (with AVR function) |
Rated current [A] (Note 4) |
HHD |
1 |
1.6 |
3 |
5 |
8 |
11 |
Overload current rating [A] (permissible overload time) |
HHD |
150% for 1 minute, 200% for 0.5 seconds |
Ambient temperature |
HHD |
-10 to +55 ºC [14 to 131 ºF]
(current derating necessary in +50 to +55 ºC [122 to 131 ºF] range) |
Rated frequency [Hz] |
50 / 60 Hz |
Input ratings |
Voltage, frequency |
Three-phase 200 to 240 V, 50/60 Hz |
Voltage, frequency fluctuation |
Voltage: +10 to -10% (interphase unbalance ratio: 2% or less) ,
Frequency: +5 to -5 % |
Rated current [A] (Note 5) |
With DCR |
HHD |
1.1 |
2 |
3.5 |
6.4 |
11.6 |
17.5 |
Without DCR |
HHD |
1.8 |
3.3 |
5.4 |
9.7 |
16.4 |
22 |
Required power supply capacity (with DCR) [kVA] (Note 6) |
HHD |
0.3 |
0.4 |
0.7 |
1.3 |
2.4 |
3.5 |
Auxiliary control power supply voltage |
– |
|
Braking |
Torque (Note 7) |
HHD |
150% |
100% |
70% |
40% |
Braking transistor |
Built-in |
Connectable resistance value [Ω] |
100 to 120 |
40 to 120 |
Braking resistor [Ω] |
Option |
DC reactor (DCR) |
Option |
EMC filter(E3E) |
Compliant with EMC Directives.
Emission: Category C2.
Immunity: 2nd Env. (EN61800-3) |
Protective construction (IEC 60529) |
IP20 enclosed type, UL open type |
Cooling system |
Natural cooling |
Fan cooling |
Weight [kg(lbs)] |
0.6
[1.3] |
0.6
[1.3] |
0.8
[1.8] |
1.2
[2.6] |
2.0
[4.4] |
2.2
[4.9] |
-
Note1
-
Standard applicable motor indicates Fuji Electric 4-pole standard motors. Select a motor not only based on inverter output (kW), but also so that the output rated current is greater than the motor rated current.
-
Note2
-
The rated capacity indicates 220 V for the 200V series, and 440 V for the 400V series.
-
Note3
-
It is not possible to output a voltage higher than the power supply voltage.
-
Note4
-
Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec.; 8 kHz HND spec.; 4 kHz
-
Note5
-
This indicates the estimated value if the power supply capacity is 500 kVA (10 times inverter capacity if inverter capacity exceeds 50 kVA), and the motor is connected to a power supply of %X = 5%.
-
Note6
-
This indicates the capacity when the motor is equipped with a DC reactor (DCR).
-
Note7
-
This is the average braking torque when performing individual operation. (This will vary based on the motor efficiency.)
-
Note8
-
Input voltage is less than 220V, standard applicable motor is 2.0kW.
-
Note9
-
Input voltage is less than 220V, standard applicable motor is 2.7kW.
-
Note10
-
HND specifications, set F80=4.
-
Note11
-
EMC filter built-in type is only available in HHD specification.