Upgrading the MICREX-SX Series SPH Programming Support Tool
February 18,2026
Fuji Electric Co., Ltd.
Log in to download the upgraded version of the programming support tool. After logging in, click the "Download documents" button to jump to the download page.
The upgraded version of the programming support tool can be downloaded from the "Download documents" page.
Applicable model
MICREX-SX Series IEC 61131-3-compliant Programming Support Tool: SX-Programmer
-
Note
-
The latest products will be shipped after the stock of the previous ones has run out.
Upgrade service details
This new service gives the registered users of Expert (D300win) direct access to the latest version of the software through the upgrade feature on the Fuji Electric FA website. Users can download the most recent version of the software from the website at their convenience.
Name of the upgrade file for SX-Programmer: ExpertUpdateV37614.exe
Main changes in the latest version: V3.7.6.14 (February 2026)
-
Supported Model transition function for SPH3000CE (Model: NP1PU-048CE). It can migrate SPH3000CE to SPH3300-048EN. (SPH3000CE is non-standard product that does not appear on the catalog.
-
SPH5000M (Soft version V30 or later version) has been applicable to IO master module (I/O expansion). (Soft version V30 is planned to be released in March 2026.)
-
Fixed so that Password-protected projects in older versions (V3.6 series) not to be opened in V3.7 because they are not subject to correct automatic conversion. (Password-protected projects saved in V3.6 series must be opened in V3.7 or later after removing the password in V3.6 series.)
-
Fixed so that the project cannot be saved if a project with the same name exists in the same folder when saving a project in the old version (V3.6 series) format.
-
New features and improvements have been added to the Text Code Worksheet.
-
Added bookmark function
-
Improved IntelliSense function
-
-
In the "Remove unreferenced variables and FB instances" command, %M address is added to "Don't remove variables located as '%I' or Q' address" option.
-
Supported simulation task.
-
Added the Backup/Restore feature of controller values which are defined in Variable Worksheet to a CSV file.
-
The message displayed when opening a project created on OS other than the one running Expert has been changed.
-
Fixed so that the timestamp of the project file (*.mwt) is not updated if the project is closed without any changes.
-
Improved the variable property/comment property screen so that it is displayed in the same position as the last time it was displayed.
-
Improved the address sorting function on the variable worksheet so that it sorts in address order.
-
We have changed the specifications so that, after switching the online monitor on or off, button operations cannot be performed for 2 seconds immediately following the switch.
-
Fixed so that the file name and path lengths are checked when changing the project name before migrating models.
-
Fixed a bug in the compiler
-
We have fixed an issue where, after migrating a multi-CPU configuration project from SPH3000 to SPH3300 and performing optimized compilation, accessing the non-retentive or retentive multi-CPU memory of the other CPU using BOOL variables within structure members, in some cases, cause a data abort error.
-
Fixed a bug that a compilation error occurred when addressing a variable in the memory area (network management information area) for the built-in FL-net compliant LAN of the SPH5000H.
-
-
Fixed a bug in the SX control utility
-
Fixed the bug that a "parameter error" occurred, causing the transfer to end or the SX control utility to be forcibly terminated when transferring backup data for the SPH2000 series to a PLC.
-
Fixed the bug that a “undefined command error” occurred, failing to back-up when transferring the data of SPH2200-048RN (NP1PM-048RN) to a PLC.
-
Fixed the bug that fails to backup and restore SPH3000D-048EZM (NP1PU-048EZM).
-
-
Fixed a bug in the Model transition function
-
Fixed the bug that the model transition cannot be executed when the Resource name of Project tree and System definition are different in uppercase and lowercase.
-
-
Fixed a bug in the system definition.
-
Fixed the bug that the fail-soft setting would automatically be set even if the fail-soft setting was canceled if a remote master module is registered under NP1L-RU1H in SPH5000H.
-
Fixed the bug that cannot export system definition including remote master if module redundancy or multi-CPU configuration is used.
-
-
Note
-
To use the project used in this version with V3.6, specify the old version (V3.6) format and save it by "Save Project As/Zip Project As".
The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
History of main version upgrades
Backward compatibility
The following table shows the project compatibility for the upgrade.
-
Note
-
We do not guarantee that the files created by V3.7.6.14 can be read into earlier version.
Product model and medium
-
There is no change in the product model (NP4H-SEDBV3) or medium (CD-R).
Upgrading procedure
-
The update file can be downloaded for free from the “Download documents” on Fuji Electric website.
-
1.
Create a new folder on the computer's hard disk.
-
2.
Download the V3.7.6.14 upgrade file (ExpertUpdateV37614.exe) to the new folder.
-
3.
Double click the downloaded file. (The upgrade is a self-extracting file.)
-
4.
The file will be extracted to the same folder.
-
5.
Double click the extracted Setup.exe file.
-
6.
Follow the prompts from the installer program to upgrade the software.
-
7.
Expert (D300win) will start up when the installation is completed. Check Info from the Help menu to make sure the version number is V 3.7.6.14.
-
Note
-
To use on after Windows Vista, administrator's right is necessary for the installation. Install the program according to the procedure below.
Select “Setup.exe” in the Explorer window after extracting the update file, and right-click this.
Select "As the administrator" from the right-clicking menu.
Following the instructions from the installer to install the program.
Upgrading precautions
-
1.
Make sure that NP4H-SEDBV3/Expert (D300win) is already installed on the computer prior to upgrading the software.
-
2.
The software cannot be upgraded if the computer does not have Expert (D300win) version 3.0.0.0 or later already installed on it.
-
3.
Do not begin the installation if the upgrade file is not exactly the same size as the file that was downloaded. If they are not the same size, throw all of them into the trash and download the upgrade file again.
-
4.
Be sure to quit all programs that are currently running (e.g., Expert (D300win), SX control utility, or message manager) prior to the installation.
-
5.
If the installation fails due to an error, try to install the software again. If the installation fails again, re-install the previous version of Expert (D300win) from the setup CD and then try to install the upgrade software again.
-
6.
You may compile all POUs and download to PLC after upgrade. It's recommended to upgrade at the timing which can stop PLC.
Log in to download the upgraded version of the programming support tool. After logging in, click the "Download documents" button to jump to the download page.
The upgraded version of the programming support tool can be downloaded from the "Download documents" page.