Standard Specifications Basic type

Three-phase 200V series

HD (High Duty) spec for heavy load
Item
Specifications
Type (FRN□□□G1S-2□)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Nominal applied motor [kW] (*1)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Output ratings Rated capacity [kVA] (*2)
1.1
1.9
3.0
4.2
6.8
10
14
18
24
28
34
45
55
68
81
107
131
Rated voltage [V] (*3)
Three-phase 200 to 240V (with AVR)
Three-phase 200 to 230V (with AVR)
Rated Current [A]
3
5
8
11
18
27
37
49
63
76
90
119
146
180
215
283
346
Overload capability
150% for 1min, 200% for 3.0s
Rated frequency [Hz]
50, 60Hz
Input ratings Main circuit power
Phases, voltage, frequency
Three-phase 200 to 240V, 50/60Hz
Three-phase 200 to 220V, 50Hz
Three-phase 200 to 230V, 60Hz
Auxiliary control power input
Phases, voltage, frequency
-
Single-phase 200 to 240V, 50/60Hz
Single-phase 200 to 230V, 50/60Hz
Auxiliary power input for fan
Phases, voltage, frequency (*5)
-
Single-phase 200 to 220V, 50Hz
Single-phase 200 to 230V, 60Hz
Voltage, frequency variations
Voltage:+10 to -15% (Voltage unbalance:2% or less (*6)) Frequency:+5 to -5%
Rated current [A] (*7) with DCR
1.6
3.2
6.1
8.9
15

21.1

28.8
42.2
57.6
71.0
84.4
114
138
167
203
282
334
without DCR
3.1
5.3
9.5
13.2
22.2
31.5
42.7
60.7
80.1
97.0
112
151
185
225
270
-
-
Required power supply capacity [kVA] (*8)
with DCR
0.6
1.2
2.2
3.1
5.2
7.4
10
15
20
25
30
40
48
58
71
98
116
Braking Torque [%] (*9)
150%
100%
20%
10 to 15%
Braking transistor
Built-in
-
Min. ohmic value [Ω]
Torque [%]
100
180%
40
180%
24
180%
16
180%
12
180%
8
180%
6
180%
4
180%
-
Built-in braking resistance
100Ω
40Ω
20Ω
-
Braking time[s]
5s
-
%ED
5
3
5
3
2
3
2
-
DC injection braking
Starting frequency:0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level:0 to 100%
DC reactor (DCR) (*10)
Optional
Standard accessory
Applicable safety standards
UL508C, C22.2No.14 (pending), EN61800-5-1:2003
Enclosure (IEC60529)
IP20 (IEC60529) closed type, UL open type (UL 50)
IP00 open type, UL open type
Cooling method
Natural cooling
Fan cooling
Weight/Mass [kg]
1.7
2
2.8
3
3
6.5
6.5
5.8
9.5
9.5
10
25
32
42
43
(*1)
Fuji's 4-pole standard motor.
(*2)
Rated capacity is calculated by assuming the output rated voltage as 220V for three-phase 200V series and 440V for three-phase 400V series.
(*3)
Output voltage cannot exceed the power supply voltage.
(*4)
When using the inverter in the ambient temperature of 40°C or over and with carrier frequency at 3kHz or higher, adjust the current under continuous running to be the value in ( ) or lower by controlling the load.
(*5)
The auxiliary power input is used as an AC fan power input when combining the unit such as high power factor PWM converter with power regenerative function. (Generally not used.)
(*6)
Interphase voltage unbalance ratio[%] = (max. voltage [V] - min. voltage [V])/3-phase average voltage [V]×67(See IEC61800-3.) Use the DC reactor (ACR: optional) when used with 2 to 3 % of unbalance ratio.
(*7)
The value is calculated on assumption that the inverter is connected with a power supply capacity of 500kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50kVA) and %X is 5%.
(*8)
Obtained when a DC reactor (DCR) is used.
(*9)
Average braking torque obtained by use of a motor. (Varies with the efficiency of the motor.)
(*10)
The 55kW DC reactor (DCR) is optional with HD spec, and is provided as a standard accessory with LD spec.