Comparison between new and old
Compare this with the existing product you are using.


The front view may not provide precise dimension comparisons.
For accurate measurements, please consult the dimension data.
Look for compatible products
Displays compatible products of the selected model.
Select your model and press the SEARCH button.
Click the Find button to reload the page and display the results
Select the model you are using.
Search result new product
New product | ||||
---|---|---|---|---|
Type | SC-03 | SC09X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: 〇 Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: ◎ Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
9 / 7 | 9 / 9 | ||
Conventional free air thermal current (Ith) [A] | 20 | 20 | ||
Main terminal screw size | M3.5 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
1NO, 1NC
(1a, 1b) |
1NO, 1NC
(1a, 1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | |
Mechanical | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 |
Sealed | 9 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 43×81×80 | 43×80×78 | |
DC operating | 43×81×107 | 43×80×96 | ||
Remarks | - | - |
New product | ||||
---|---|---|---|---|
Type | SC-0 | SC12X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: 〇 Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: ◎ Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
12 / 9 | 12 / 12 | ||
Conventional free air thermal current (Ith) [A] | 20 | 20 | ||
Main terminal screw size | M3.5 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
1NO, 1NC
(1a, 1b) |
1NO, 1NC
(1a, 1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | |
Mechanical | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 |
Sealed | 9 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 43×81×80 | 43×80×78 | |
DC operating | 43×81×107 | 43×80×96 | ||
Remarks | - | - |
New product | |||||
---|---|---|---|---|---|
Type | SC-05 | SC12X + SZ3AS1 (Side mounting) |
SC12X + SZ3A11 (Front mounting) |
||
Appearance | ![]() |
![]()
|
![]()
|
||
Compatibility | - |
Dimensions: ◎ Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: 〇 Performance: 〇 ◎: Compatible |
Dimensions: × Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: 〇 Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
12 / 9 | 12 / 12 | 12 / 12 | ||
Conventional free air thermal current (Ith) [A] | 20 | 20 | 20 | ||
Main terminal screw size | M3.5 | M3.5 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO, 1NO+1NC, 2NC
(2a, 1a1b, 2b) |
2NO+1NC, 1NO+2NC
(2a1b, 1a2b) |
2NO+1NC, 1NO+2NC
(2a1b, 1a2b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | 2 | |
Mechanical | 10 | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 | 66 |
Sealed | 9 | 7.2 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 53×81×80 | 53×80×78 | 43×80×111 | |
DC operating | 53×81×107 | 53×80×96 | 43×80×129 | ||
Remarks | - | Terminal numbers and terminal arrangement will be changed. |
New product | ||||
---|---|---|---|---|
Type | SC-4-0 | SC18X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: × Screw mounting dimensions: ◎ Screw size: × Auxiliary contact configuration: ◎ Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
16 / 13 | 18 / 18 | ||
Conventional free air thermal current (Ith) [A] | 25 | 25 | ||
Main terminal screw size | M4 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
1NO, 1NC
(1a, 1b) |
1NO, 1NC
(1a, 1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
1.5 | 1.5 | |
Mechanical | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 |
Sealed | 9 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 53×81×81 | 43×80×78 | |
DC operating | 53×81×108 | 43×80×96 | ||
Remarks | - | - |
New product | ||||
---|---|---|---|---|
Type | SC-4-1 | SC20X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: ◎ Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: ◎ Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
22 / 17 | 20 / 20 | ||
Conventional free air thermal current (Ith) [A] | 32 | 32 | ||
Main terminal screw size | M4 | M4 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
1NO, 1NC
(1a, 1b) |
1NO, 1NC
(1a, 1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | |
Mechanical | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 90 |
Sealed | 9 | 9 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 4.6(2.4) | |
Sealed | 7 | 4.6(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 53×81×81 | 53×80×82 | |
DC operating | 53×81×108 | 53×80×108 | ||
Remarks | - | - |
New product | ||||
---|---|---|---|---|
Type | SC-5-1 | SC20D | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: ◎ Screw mounting dimensions: ◎ Screw size: ◎ Auxiliary contact configuration: ◎*1 Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
22 / 17 | 20 / 20 | ||
Conventional free air thermal current (Ith) [A] | 32 | 32 | ||
Main terminal screw size | M4 | M4 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO, 1NO+1NC, 2NC
(2a, 1a1b, 2b) |
2NO, 1NO+1NC, 2NC
(2a, 1a1b, 2b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | |
Mechanical | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 90 |
Sealed | 9 | 9 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 4.6(2.4) | |
Sealed | 7 | 4.6(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 64×81×81 | 64×80×82 | |
DC operating | 64×81×108 | 64×80×108 | ||
Remarks | - | *1: If you are using 2NO+2NC (2a2b), please refer to the catalog for details. |
New product | ||||||
---|---|---|---|---|---|---|
Type | SC-N1 | SC26X | SC26D | SC32X | ||
Appearance | ![]() |
![]()
|
![]()
|
![]()
|
||
Compatibility | - |
Dimensions: × Screw mounting dimensions: 〇*2 Screw size: × Auxiliary contact configuration: × Performance: 〇 ◎: Compatible |
Dimensions: × Screw mounting dimensions: 〇*2 Screw size: × Auxiliary contact configuration: × Performance: 〇 ◎: Compatible |
Dimensions: × Screw mounting dimensions: 〇*2 Screw size: × Auxiliary contact configuration: × Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
32 / 25 | 26 / 26 | 26 / 26 | 32 / 32 | ||
Conventional free air thermal current (Ith) [A] | 50 | 50 | 50 | 50 | ||
Main terminal screw size | M5 | M4 | M4 | M4 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO+2NC
(2a2b) |
1NO, 1NC
(1a, 1b) |
2NO, 1NO+1NC, 2NC
(2a, 1a1b, 2b) |
1NO, 1NC
(1a, 1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | 2 | 2 | |
Mechanical | 10 | 10 | 10 | 10 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 120 | 90 | 90 | 90 |
Sealed | 12.7 | 9 | 9 | 9 | ||
DC operating [W]
() indicates low |
Inrush | 9 | 4.6(2.4) | 4.6(2.4) | 4.6(2.4) | |
Sealed | 9 | 4.6(2.4) | 4.6(2.4) | 4.6(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 74×87×96 | 53×80×82 | 64×80×82 | 53×80×82 | |
DC operating | 74×87×122 | 53×80×108 | 64×80×108 | 53×80×108 | ||
Remarks | - | *2: Please use the adapter plate (SZ3AP26D). |
New product | ||||||
---|---|---|---|---|---|---|
Type | SC-N2 | SC38X | SC38D | SC40X | ||
Appearance | ![]() |
![]()
|
![]()
|
![]()
|
||
Compatibility | - |
Dimensions: × Screw mounting dimensions: 〇*3 Screw size: × Auxiliary contact configuration: × Performance: 〇 ◎: Compatible |
Dimensions: × Screw mounting dimensions: 〇*3 Screw size: × Auxiliary contact configuration: ×*1 Performance: 〇 ◎: Compatible |
Dimensions: × Screw mounting dimensions: × Screw size: 〇 Auxiliary contact configuration: × Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
40 / 32 | 38 / 38 | 38 / 38 | 40 / 40 | ||
Conventional free air thermal current (Ith) [A] | 60 | 50 | 50 | 80 | ||
Main terminal screw size | M5 | M4 | M4 | M5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO+2NC
(2a2b) |
1NO, 1NC
(1a, 1b) |
2NO, 1NO+1NC, 2NC
(2a, 1a1b, 2b) |
1NO+1NC
(1a1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | 2 | 2 | |
Mechanical | 10 | 10 | 10 | 5 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 120 | 90 | 90 | 120 |
Sealed | 12.7 | 9 | 9 | 12.7 | ||
DC operating [W]
() indicates low |
Inrush | 9 | 4.6(2.4) | 4.6(2.4) | 7.5 | |
Sealed | 9 | 4.6(2.4) | 4.6(2.4) | 7.5 | ||
External Dimensions
W × H × D [mm] |
AC operating | 74×87×96 | 53×80×82 | 64×80×82 | 64×89×93 | |
DC operating | 74×87×122 | 53×80×108 | 64×80×108 | 64×89×125 | ||
Remarks | - | *3: Please use the adapter plate (SZ3AP26D). |
*1: If you are using 2NO+2NC (2a2b), please refer to the catalog for details. *3: Please use the adapter plate (SZ3AP26D). |
- |
New product | ||||
---|---|---|---|---|
Type | SC-N2S | SC50X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: × Screw mounting dimensions: 〇*4 Screw size: × Auxiliary contact configuration: ×*1 Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
50 / 48 | 50 / 50 | ||
Conventional free air thermal current (Ith) [A] | 80 | 80 | ||
Main terminal screw size | M6 | M5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO+2NC
(2a2b) |
1NO+1NC
(1a1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 2 | |
Mechanical | 5 | 5 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 180 | 120 |
Sealed | 13.3 | 12.7 | ||
DC operating [W]
() indicates low |
Inrush | 12 | 7.5 | |
Sealed | 12 | 7.5 | ||
External Dimensions
W × H × D [mm] |
AC operating | 88×110×111 | 64×89×93 | |
DC operating | 88×110×130 | 64×89×125 | ||
Remarks | - |
*1: If you are using 2NO+2NC (2a2b), please refer to the catalog for details. *4: Please use the adapter plate (SZ3AP50X). |
New product | ||||
---|---|---|---|---|
Type | SC-N3 | SC65X | ||
Appearance | ![]() |
![]()
|
||
Compatibility | - |
Dimensions: × Screw mounting dimensions: 〇*5 Screw size: × Auxiliary contact configuration: ×*1 Performance: 〇 ◎: Compatible |
||
IEC / JIS Rating [A]
AC-3, AC-3e, 380-440V |
65 / 65 | 65 / 65 | ||
Conventional free air thermal current (Ith) [A] | 100 | 80 | ||
Main terminal screw size | M6 | M5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
2NO+2NC
(2a2b) |
1NO+1NC
(1a1b) |
||
Durability [Million times] |
Electrical
AC-3, AC-3e, 220V |
2 | 1.3 | |
Mechanical | 5 | 5 | ||
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 180 | 120 |
Sealed | 13.3 | 12.7 | ||
DC operating [W]
() indicates low |
Inrush | 12 | 7.5 | |
Sealed | 12 | 7.5 | ||
External Dimensions
W × H × D [mm] |
AC operating | 88×110×111 | 64×89×93 | |
DC operating | 88×110×130 | 64×89×125 | ||
Remarks | - |
*1: If you are using 2NO+2NC (2a2b), please refer to the catalog for details. *5: Please use the adapter plate (SZ3AP50X). |
New product | ||||
---|---|---|---|---|
Type | SH-4 | SCH4X | ||
Appearance | ![]() |
![]() |
||
Conventional free air thermal current (Ith) [A] | 10 | 10 | ||
Minimum switching voltage | DC5V | DC5V | ||
Minimum switching current | 3mA | 3mA | ||
Terminal screw size | M3.5 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
Standard |
4NO, 3NO+1NC, 2NO+2NC
(4a, 3a1b, 2a2b) |
4NO, 3NO+1NC, 2NO+2NC
(4a, 3a1b, 2a2b) |
|
Low consumption | - |
4NO, 3NO+1NC, 2NO+2NC
(4a, 3a1b, 2a2b) |
||
Maximum number of auxiliary contacts
(Additional auxiliary combination) |
Standard coil | 8(4+4) | 8(4+4) | |
Low consumption | - | 6(4+2) | ||
Durability [Million times] | Mechanical | 10 | 10 | |
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 |
Sealed | 9 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 43×81×80 | 43×80×78 | |
DC operating | 43×81×107 | 43×80×96 | ||
Remarks | - | - |
New product | |||||
---|---|---|---|---|---|
Type | SH-5 | SCH4X + SZ3A (Front mounting) |
SCH4X + SZ3AS (Side mounting) |
||
Appearance | ![]() |
![]() |
![]() |
||
Conventional free air thermal current (Ith) [A] | 10 | 10 | 10 | ||
Minimum switching voltage | DC5V | DC5V | DC5V | ||
Minimum switching current | 3mA | 3mA | 3mA | ||
Terminal screw size | M3.5 | M3.5 | M3.5 | ||
Number of auxiliary contacts
("1NO, 1NC" indicates 1NO or 1NC) |
Standard |
5NO, 4NO+1NC, 3NO+2NC, 2NO+3NC, 1NO+4NC, 5NC (5a, 4a1b, 3a2b, 2a3b, 1a4b, 5b) |
8NO, 7N1+1NC, 6NO+2NC, 5NO+3NC, 4NO+4NC, 6NO, 5NO+1NC, 4NO+2NC, 3NO+3NC, 2NO+4NC (8a, 7a1b, 6a2b, 5a3b, 4a4b, |
6NO+2NC, 5NO+3NC, 4NO+4NC
(6a2b, 5a3b, 4a4b) *6 5NO+1NC, 4NO+2NC, 3NO+3NC(5a1b, 4a2b, 3a3b, 1a5b) *7 |
|
Low consumption | - |
6NO, 5NO+1NC, 4NO+2NC, 3NO+3NC, 2NO+4NC (6a, 5a1b, 4a2b, 3a3b, 2a4b) |
5NO+1NC, 4NO+2NC, 3NO+3NC
(5a1b, 4a2b, 3a3b) |
||
Maximum number of auxiliary contacts
(Additional auxiliary combination) |
Standard coil | 9(5+4) | 8(4+5) | 8(4+4) | |
Low consumption | - | 6(4+3) | 6(4+2) | ||
Durability [Million times] | Mechanical | 10 | 10 | 10 | |
Magnet Capacity |
AC operating [VA]
200V 50Hz |
Inrush | 90 | 66 | 66 |
Sealed | 9 | 7.2 | 7.2 | ||
DC operating [W]
() indicates low |
Inrush | 7 | 3.9(2.4) | 3.9(2.4) | |
Sealed | 7 | 3.9(2.4) | 3.9(2.4) | ||
External Dimensions
W × H × D [mm] |
AC operating | 53×81×80 | 43×80×111 |
53×80×78 *1 64×80×78 *2 |
|
DC operating | 53×81×107 | 43×80×129 |
53×80×96 *6 64×80×96 *7 |
||
Remarks | - | Terminal numbers and terminal arrangement will be changed. |
Terminal numbers and terminal arrangement will be changed. *6 In case you add one auxiliary contact unit. *7 In case you add two auxiliary contact units. |

You can download the list of compatible products.