Basic specifications
Applicable motor rated speed | 3000 [r/min] | |||||||||||
Applicable motor output | 0.05kW | 0.1kW | 0.2kW | 0.4kW | 0.75kW | |||||||
Type RYC□□□ | D3-VVT2 | 500 | 101 | 201 | 401 | 751 | ||||||
C3-VVT2 | ||||||||||||
B3-VVT2 | ||||||||||||
Outer frame number | Frame 1 | Frame 2 | ||||||||||
Mass [kg] | 1.0 | 1.5 | ||||||||||
Power supply |
Main power supply |
Phase | Single-phase | Single-phase, 3-phase | ||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% (-10 to +10% at Single-phase) | |||||||||||
Control power supply |
Phase | Single-phase | ||||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% 50/60 Hz |
|||||||||||
Control system | IGBT PWM sinusoidal PWM drive | |||||||||||
Feedback | 17-bit serial encoder (incremental) | |||||||||||
Functions, input/output signals |
Sequence input (CONT1 to 5) |
(1) Servo ON, (2) +over-travel, (3) -over-travel, (4) emergency stop, (5) P-action, (6) free run command, (7) anti-resonant frequency selection 1, (8) anti-resonant frequency selection 2, (9) control mode switching, (10) external regenerative resistor overheat, (11) alarm reset These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
||||||||||
Sequence output (OUT1 to 4) |
(1) Servo ready, (2) positioning complete, (3) servo alarm detection a-contact, (4) servo alarm detection b-contact, (5) dynamic braking control, (6) over-travel detection, (7) emergency stop detection, (8) deviation zero, (9) speed zero, (10) current limit detection, (11) brake timing These functions can be assigned to sequence outputs OUT1 to OUT4 and used. |
|||||||||||
Encoder signa dividing output |
Dividing setting | Pulse output setting 16 to 32768 (pulses/rev) | ||||||||||
Signal form | (1) Line driver output A-phase, B-phase, and Z-phase, (2) open collector output Z-phase | |||||||||||
Monitor output | Analog voltage output for signal measurement (alternating, pulsating) × 2 |
|||||||||||
Position control |
Max. command pulse frequency | Pulse frequency (max.) command input 1 MHz (differential), 200 kHz (open collector), dividing output 500 kHz (differential) | ||||||||||
Input pulse signal form | Compatible with two systems: (1) RS-422 line driver signals and (2) open collector signals | |||||||||||
Input pulse type | Selectable from (1) command pulse/command sign, (2) forward operation/reverse operation pulse, and (3) two 90° phase-different signals | |||||||||||
Command pulse correction |
|
|||||||||||
Position control input | (1) Command pulse correction α selection 1, (2) command pulse correction a selection 2, (3) deviation clear, (4) command pulse disabled These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Speed control |
Speed control range | 1:5000 |
||||||||||
Acceleration /deceleration time setting |
0 to 10 s / 2000 r/min, acceleration and deceleration times can be set separately, two acceleration times and deceleration times can be set, S-curve acceleration/deceleration is possible. | |||||||||||
External speed command input | Torque control by analog voltage commands, ±10 V input, the voltage-speed scale and offset can be set by setting parameters. | |||||||||||
Internal speed setting | Three speeds can be set by setting internal parameters. | |||||||||||
Speed control input | (1) Multi-speed selection 1, (2) multi-speed selection 2, (3) forward operation, (4) reverse operation, (5) acceleration/deceleration time selection These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Torque control | External torque command input | Speed control by analog voltage commands, ±10 V input, the voltage-torque scale and offset can be set by setting parameters. | ||||||||||
Torque control input | (1) Forward operation and (2) reverse operation can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) | |||||||||||
Regenerative braking | Regenerative braking to DC intermediate circuit, the regenerative resistor can be externally installed. | |||||||||||
Additional functions | Zero clamp function, vibration suppressing control, notch filter, easy tuning, brake timing output, etc. | |||||||||||
Protection | Overcurrent (OC1, OC2), overspeed (OS), overvoltage (Hv), encoder error (Et), control power error (Ct), memory error (dE), regenerative transistor overheat (rH2) encoder communication error (EC), CONT duplication (Cnt), overload (OL), insufficient voltage (LV), regenerative resistor overheat (rH1), excessive deviation (OF), amplifier overheat (AH) |
|||||||||||
Working conditions | Installation place | For indoor use at max. altitude of 1,000 m or below. The installation place shall be free from dust, corrosive gas, or direct sunlight. To meet European standards: Pollution degree = 2, overvoltage category = | ||||||||||
Temperature/humidity | -10 to 55 °C, 10 to 90 %RH (without condensation) | |||||||||||
Vibration/shock resistance | 4.9m/s2 {0.5G} , 19.6m/s2 {2G} | |||||||||||
Standards | Conforming to UL/cUL (UL508c) and CE Mark (low voltage directive EN50178) |
*1: Functions you want to keep ON at all times can be used without wiring (up to four functions can be set by setting parameters as normally ON signals).
Applicable motor rated speed | 2000[r/min] | |||||||||||
Applicable motor output | 0.5kW | 0.75kW | 1kW | 1.5kW | 2kW | |||||||
Type RYC□□□ | D3-VVT2 | |||||||||||
C3-VVT2 | 501 | 751 | 102 | 152 | 202 | |||||||
B3-VVT2 | ||||||||||||
Outer frame number | Frame 2 | Frame 3 | ||||||||||
Mass [kg] | 1.5 | 2.5 | ||||||||||
Power supply |
Main power supply |
Phase | Single-phase, 3-phase | 3-phase | ||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% (-10 to +10% at Single-phase) | |||||||||||
Control power supply |
Phase | Single-phase | ||||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% 50/60 Hz |
|||||||||||
Control system | IGBT PWM sinusoidal PWM drive | |||||||||||
Feedback | 17-bit serial encoder (incremental) | |||||||||||
Functions, input/output signals |
Sequence input (CONT1 to 5) |
(1) Servo ON, (2) +over-travel, (3) -over-travel, (4) emergency stop, (5) P-action, (6) free run command, (7) anti-resonant frequency selection 1, (8) anti-resonant frequency selection 2, (9) control mode switching, (10) external regenerative resistor overheat, (11) alarm reset These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
||||||||||
Sequence output (OUT1 to 4) |
(1) Servo ready, (2) positioning complete, (3) servo alarm detection a-contact, (4) servo alarm detection b-contact, (5) dynamic braking control, (6) over-travel detection, (7) emergency stop detection, (8) deviation zero, (9) speed zero, (10) current limit detection, (11) brake timing These functions can be assigned to sequence outputs OUT1 to OUT4 and used. |
|||||||||||
Encoder signa dividing output |
Dividing setting | Pulse output setting 16 to 32768 (pulses/rev) | ||||||||||
Signal form | (1) Line driver output A-phase, B-phase, and Z-phase, (2) open collector output Z-phase | |||||||||||
Monitor output | Analog voltage output for signal measurement (alternating, pulsating) × 2 |
|||||||||||
Position control |
Max. command pulse frequency | Pulse frequency (max.) command input 1 MHz (differential), 200 kHz (open collector), dividing output 500 kHz (differential) | ||||||||||
Input pulse signal form | Compatible with two systems: (1) RS-422 line driver signals and (2) open collector signals | |||||||||||
Input pulse type | Selectable from (1) command pulse/command sign, (2) forward operation/reverse operation pulse, and (3) two 90° phase-different signals | |||||||||||
Command pulse correction |
|
|||||||||||
Position control input | (1) Command pulse correction α selection 1, (2) command pulse correction a selection 2, (3) deviation clear, (4) command pulse disabled These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Speed control |
Speed control range | 1:5000 |
||||||||||
Acceleration /deceleration time setting |
0 to 10 s / 2000 r/min, acceleration and deceleration times can be set separately, two acceleration times and deceleration times can be set, S-curve acceleration/deceleration is possible. | |||||||||||
External speed command input | Torque control by analog voltage commands, ±10 V input, the voltage-speed scale and offset can be set by setting parameters. | |||||||||||
Internal speed setting | Three speeds can be set by setting internal parameters. | |||||||||||
Speed control input | (1) Multi-speed selection 1, (2) multi-speed selection 2, (3) forward operation, (4) reverse operation, (5) acceleration/deceleration time selection These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Torque control | External torque command input | Speed control by analog voltage commands, ±10 V input, the voltage-torque scale and offset can be set by setting parameters. | ||||||||||
Torque control input | (1) Forward operation and (2) reverse operation can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) | |||||||||||
Regenerative braking | Regenerative braking to DC intermediate circuit, the regenerative resistor can be externally installed. | |||||||||||
Additional functions | Zero clamp function, vibration suppressing control, notch filter, easy tuning, brake timing output, etc. | |||||||||||
Protection | Overcurrent (OC1, OC2), overspeed (OS), overvoltage (Hv), encoder error (Et), control power error (Ct), memory error (dE), regenerative transistor overheat (rH2) encoder communication error (EC), CONT duplication (Cnt), overload (OL), insufficient voltage (LV), regenerative resistor overheat (rH1), excessive deviation (OF), amplifier overheat (AH) |
|||||||||||
Working conditions | Installation place | For indoor use at max. altitude of 1,000 m or below. The installation place shall be free from dust, corrosive gas, or direct sunlight. To meet European standards: Pollution degree = 2, overvoltage category = | ||||||||||
Temperature/humidity | -10 to 55 °C, 10 to 90 %RH (without condensation) | |||||||||||
Vibration/shock resistance | 4.9m/s2 {0.5G} , 19.6m/s2 {2G} | |||||||||||
Standards | Conforming to UL/cUL (UL508c) and CE Mark (low voltage directive EN50178) |
*1: Functions you want to keep ON at all times can be used without wiring (up to four functions can be set by setting parameters as normally ON signals).
Applicable motor rated speed | 1500[r/min] | |||||||||||
Applicable motor output | 0.5kW | 0.85kW | 1.3kW | 1.8kW | 2.9kW | |||||||
Type RYC□□□ | D3-VVT2 | |||||||||||
C3-VVT2 | ||||||||||||
B3-VVT2 | 501 | 851 | 132 | 182 | 292 | |||||||
Outer frame number | Frame 2 | Frame 3 | Frame 3A | |||||||||
Mass [kg] | 1.5 | 2.5 | 2.6 | |||||||||
Power supply |
Main power supply |
Phase | Single-phase, 3-phase | 3-phase | ||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% (-10 to +10% at Single-phase) | |||||||||||
Control power supply |
Phase | Single-phase | ||||||||||
Voltage frequency |
AC200 to 230 V -15 to +10% 50/60 Hz |
|||||||||||
Control system | IGBT PWM sinusoidal PWM drive | |||||||||||
Feedback | 17-bit serial encoder (incremental) | |||||||||||
Functions, input/output signals |
Sequence input (CONT1 to 5) |
(1) Servo ON, (2) +over-travel, (3) -over-travel, (4) emergency stop, (5) P-action, (6) free run command, (7) anti-resonant frequency selection 1, (8) anti-resonant frequency selection 2, (9) control mode switching, (10) external regenerative resistor overheat, (11) alarm reset These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
||||||||||
Sequence output (OUT1 to 4) |
(1) Servo ready, (2) positioning complete, (3) servo alarm detection a-contact, (4) servo alarm detection b-contact, (5) dynamic braking control, (6) over-travel detection, (7) emergency stop detection, (8) deviation zero, (9) speed zero, (10) current limit detection, (11) brake timing These functions can be assigned to sequence outputs OUT1 to OUT4 and used. |
|||||||||||
Encoder signa dividing output |
Dividing setting | Pulse output setting 16 to 32768 (pulses/rev) | ||||||||||
Signal form | (1) Line driver output A-phase, B-phase, and Z-phase, (2) open collector output Z-phase | |||||||||||
Monitor output | Analog voltage output for signal measurement (alternating, pulsating) × 2 |
|||||||||||
Position control |
Max. command pulse frequency | Pulse frequency (max.) command input 1 MHz (differential), 200 kHz (open collector), dividing output 500 kHz (differential) | ||||||||||
Input pulse signal form | Compatible with two systems: (1) RS-422 line driver signals and (2) open collector signals | |||||||||||
Input pulse type | Selectable from (1) command pulse/command sign, (2) forward operation/reverse operation pulse, and (3) two 90° phase-different signals | |||||||||||
Command pulse correction |
|
|||||||||||
Position control input | (1) Command pulse correction α selection 1, (2) command pulse correction a selection 2, (3) deviation clear, (4) command pulse disabled These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Speed control |
Speed control range | 1:5000 |
||||||||||
Acceleration /deceleration time setting |
0 to 10 s / 2000 r/min, acceleration and deceleration times can be set separately, two acceleration times and deceleration times can be set, S-curve acceleration/deceleration is possible. | |||||||||||
External speed command input | Torque control by analog voltage commands, ±10 V input, the voltage-speed scale and offset can be set by setting parameters. | |||||||||||
Internal speed setting | Three speeds can be set by setting internal parameters. | |||||||||||
Speed control input | (1) Multi-speed selection 1, (2) multi-speed selection 2, (3) forward operation, (4) reverse operation, (5) acceleration/deceleration time selection These functions can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) |
|||||||||||
Torque control | External torque command input | Speed control by analog voltage commands, ±10 V input, the voltage-torque scale and offset can be set by setting parameters. | ||||||||||
Torque control input | (1) Forward operation and (2) reverse operation can be assigned to sequence inputs CONT1 to CONT5 and used. (*1) | |||||||||||
Regenerative braking | Regenerative braking to DC intermediate circuit, the regenerative resistor can be externally installed. | |||||||||||
Additional functions | Zero clamp function, vibration suppressing control, notch filter, easy tuning, brake timing output, etc. | |||||||||||
Protection | Overcurrent (OC1, OC2), overspeed (OS), overvoltage (Hv), encoder error (Et), control power error (Ct), memory error (dE), regenerative transistor overheat (rH2) encoder communication error (EC), CONT duplication (Cnt), overload (OL), insufficient voltage (LV), regenerative resistor overheat (rH1), excessive deviation (OF), amplifier overheat (AH) |
|||||||||||
Working conditions | Installation place | For indoor use at max. altitude of 1,000 m or below. The installation place shall be free from dust, corrosive gas, or direct sunlight. To meet European standards: Pollution degree = 2, overvoltage category = | ||||||||||
Temperature/humidity | -10 to 55 °C, 10 to 90 %RH (without condensation) | |||||||||||
Vibration/shock resistance | 4.9m/s2 {0.5G} , 19.6m/s2 {2G} | |||||||||||
Standards | Conforming to UL/cUL (UL508c) and CE Mark (low voltage directive EN50178) |