FUJI ELECTRIC Programmable Operation Display (POD) UG Series
Information on Version Upgrade of UG00S Screen Programming Software
1. Target Models
  Screen programming software for POD UG Series
Model Specification Latest version
UG00S-CWV3 Screen programming software, Japanese/English version V3.2.32.0
2. Major Revisions
(1) Local Ethernet window supports its port number setting
Whereas local station's port number had to be set only using the Editor, it can now be set using the Ethernet window on the local station.
(2)Model supporting temperature control networks has been added.
Maker Model
Sanmei Electronics Cuty Axis 3 (Servo)
(3) Connectable PLCs have been added.
Maker Model
SIEMENS S7-400 (Multi CPU , Ethernet )
- Modbus TCP/IP (Ethernet Sub Station)
3. Revision History (Major Revisions)
(1)V3.2.31.0
(a)Specification change of event timer macro
Previously, when plural event timer macros were set and plural event timer macros were being continuously executed, SW operation was not allowed. With this specification change, the interruption of SW operation can now be made between event timer macros.
(2)V3.2.30.0
(a)Model supporting temperature control networks has been added.
 
Maker Model
UNIPULSE F800
DANFOSS VLT
SUNX LP-W052
(b)Connectable PLCs have been added. (UG30)
Maker Model
UNITRONICS M90/M91/Vision series
AUTOMATION DIRECT Direct Logic (ModbusRTU)
LS GLOFA GMR (Ethernet)
KOYO ELECTRONICS INDUSTRIES S7-300/400(Ethernet)
(3)V3.2.29.0
(a)MICREX-SX SPH300EX support
  SPH300EX for a July 2006 release is now supported in advance.
(b)UG630 analog RGB input/output optional unit
A UG630 analog RGB input/output optional unit (UG00A-RIS/ROS) for a June 2006 release is now supported.
(c)UG630 video screen enlarged display
In UG630, video displays are now enlarged to SVGA and XGA. 800 x 600, 800 x 300, 1024 x 768, 1024 x 384 size available (Background snap not supported).
(d)SIEMENS-made PLC MPI adapter support (UG30, Simple POD)
SIEMENS-made PLC MPI adapter for a June 2006 release is now supported.
(e)PLCs with ladder transfer function added. (UG30)
Maker Model
MITSUBISHI ELECTRIC Q00J/00/01 CPU
MATSUSHITA ELECTRIC WORKS MEWNET
SAMSUNG SECNET
(f)Model supporting temperature control networks has been added.
Maker Model
MITSUBISHI ELECTRIC MR-J2S-CP
HONEYWELL DC1000
YAMATAKE SDC35/36
(g)Connectable PLCs have been added. (UG30)
Maker Model
SIEMENS S7-300/400(Ethernet)
(4)V3.2.28.0
(a)Recipe file delete function (UG30)
  Unnecessary recipe files on a CF card can now be deleted in the recipe mode of the POD, without having to use a computer.
(b)Independent transmission of Ethernet network tables via the editor
When the network table content is changed, the network table itself can now be independently transmitted using the editor. Previously, the entire screen data had to be transmitted. This improvement greatly reduces transmission time.
(c)Support for RS-422 port on Mitsubishi Q-series CPU Units
Support for RS-232C-to-RS-422 conversion cables allows RS-422 to be selected when connecting to the port of a Mitsubishi Q-series (QnH (Q) Series) CPU Unit.
(d)PLCs with ladder transfer function added
Maker Model
MITSUBISHI ELECTRIC MELSEC-A CPU
Note: This function requires a special cable (UG30C-MA□).
(e)Model with PLC 2-way connection capability added.
Maker Model
Rockwell Automation SLC500
(f)Model supporting temperature control networks has been added.
Maker Model
TOSHIBA SCHNEIDER INVERTER VF-S11
MITSUBISHI ELECTRIC MR-J3
(g)Connectable PLCs have been added.
Maker Model
MITSUBISHI ELECTRIC MELSEC-Q (Multi CPU) (Ethernet)
LS XGT/XGK(Ethernet)
TOYO DENKI SEIZO μGPCsx(Ethernet)
Rockwell Automation 1761-NET-ENI Ethernet interface(SLC500)

HITACHI INDUSTRIAL
EQUIPMENT SYSTEMS

EH-150 EHV
EH-150 EHV(Ethernet)
(5)V3.2.27.3(V3.2.27.0)
(a)UG630 series support
(b)Adjustable retries following an Ethernet communications error
The number of retries, which was formerly fixed at three, can now be set to any desired number.
(c)Independent transmission of Ethernet network tables
When the network table content is changed, the network table itself can now be independently transmitted (via a CF card). Previously, the entire screen data had to be transmitted. This greatly reduces transmission time.
(d)Local window support for Chinese and Korean languages
Chinese (simplified or traditional characters) and Korean are now supported at the local window level.
(e)Network list files supported for all FUJI F-MPC series temperature controller models
List files have been added to the temperature control network for the FePSU and all models in the F-MPC series.
(f)CVFD macro $s99 option added
In the CVFD macro, when real numbers (floating points) are converted to decimals, until now the last decimal point has been determined by simply rounding off to the nearest unit. A new function has been added that also allows any fraction to be counted as one, or omitted entirely.
(g)Model supporting temperature control networks has been added.
Maker Model
FUJI ELECTRIC FA FRENIC-Multi
FUJI ELECTRIC SYSTEMS PXG (Modbus)
PXH (Modbus)
PHR (Modbus)
SUNX LP-V10
SICK DME3000
(h)Principal Improvement
We corrected the problem that was preventing the sampling and recipe functions of UG30-series PODs from accessing CSV files on CF cards.
(6)V3.2.26.0
(a) Direct data transfer between external devices using macro commands BMOV, CVMOV
Whereas data previously had to be sent first to internal memory in order to transfer it between external devices (PLCs, temperature controllers, and memory cards), it can now be transferred directly.
(b) UG-Link local station nodes increased
The number of local station nodes that can be set has been increased from the previous 1 to 31 to 1 to 254. Local station nodes can now also be set using the POD local window.
(c)Password protection for transferring screen data to a CF card
A password can be set for transferring screen data from the POD to a CF (Compact Flash) card.
(d)Screen switching method revised for local window expansion function setting
The expansion function setting window of the local window is switched to set the modem baud rate for remote maintenance. The method for switching this window has been revised.
Before revision: Switching was done using the Editor:MJ1 switch of the local main window.
After revision: Switching is done by simultaneously pressing function switch F5 and the Editor:MJ1 switch of the local main window.
(e)Alarm sample setting item added
A setting item that prevents the alarm from being cancelled while it is being generated has been added to the Environment Setting tab of the Unit Settings.
(f)LG company name revised
The LG company name has been changed to LS.
(g)MICREX-SX series 24-bit address supported
The address capability has been expanded to support 24-bit addresses when MICREX-SX is selected for the simulator.
(h)Capacity increased for Mitsubishi Q series ladder monitor data
The ladder data capacity has been expanded from 1MB to 4MB.
(i) New models compatible with printers added
Maker Model Interface
EPSON EPSON STYLUS C65 USB,parallel
(j) Model supporting temperature control networks has been added.
Maker Model
FUJI ELECTRIC FA HFR-C11K
SIEMENS URR Protocol
YAMATAKE AHC2001 + DCP31/32
(k)Connectable PLCs have been added.
Maker Model
LS XGT/XGK
EATON Cutler-Hammer ELC
Rockwell Automation PLC-5/SLC500/Control Logix(Ethernet)
4. Compatibility with Conventional Products
Compatibility of screen data is shown below.
  Screen data programmed by earlier versions Screen data programmed by V3.2.32.0
UG00 S-CW (V3) earlier versions Ο
UG00S-CWV3 V3.2.32.0 Ο Ο
Screen data incorporating any functions of the new version cannot be used by earlier versions of the screen programming software.
5. Upgrade Procedure
(1) Create a new folder in any location of the PC's hard disk.
(2) Download the V3.2.32.0 update file (UGUpdate_e V3.2.32.0.exe) to the new folder.
(3) Double-click the update file (self-extracting compressed file).
(4) Files are extracted in the folder.
(5) Among the extracted files, double-click the setup.exe in the "UGUpdate_e" folder.
(6) Install the software according to the installer's instructions.
(7) When the installation procedure is completed, activate UG00S and make sure the version number has been updated to V3.2.32.0 using the Help menu. If V3.2.32.0 is displayed, installation has completed successfully.
6. Notes on Upgrade
(1) Install the update file to the PC in which UG00S-3W/3 WE/CW is installed.
(2) The update file can be used only when the version of UG00S-3W/3 WE/CW already installed is V2.0.0.0 or later.
(3) If the size of the update file differs from that of the downloaded file, discard the file and download it again.
(4) The update file does not include Gothic font files, 3D Parts files, and English Gothic and Times font files. If you are using UG00S-3W/3WE (V2.3 or earlier), you need to download and install Gothic font files and 3D Parts file in addition to the update file. (If you are using UG00S-CW, you can skip this procedure.)
(5) The update file includes the main program and I/F drivers for PLC.

You can download the screen creation software UG00S-CWV upgrade version from the Technical Information Service Screen (Free membership).

Enter the Technical Information Service Site