2. Major Revisions |
 |
(1) MJ2 setting for PLC communications with UG230A-DCL mounted to the UG230 |
 |
MJ2 can now be selected as the PLC communications port setting when the UG230A-DCL expansion unit is mounted to the UG230. |
 |
(2) UG30A-VIS video image edge enhancing display mode added |
 |
A function has been added to enhance the edges of text or graphics that are superimposed onto video images in order to provide images with sharper contour delineation. |
 |
(3) I/O monitor bit No. display for Mitsubishi Q-series ladder monitor function |
 |
A bit No. display has been added to the I/O monitor binary display of the Mitsubishi Q-series ladder monitor function. |
 |
(4) DEC/BCD selection added to temperature control network/PLC 2-way setting |
 |
A DEC/BCD selection has been added to the previous DEC fixed setting for the temperature control memory. |
 |
(5) Recipe file data acquisition macro added |
 |
A recipe file data acquisition macro (GET_RECIPE_FILEINFO) has been added to simplify the retrieval of line and column numbers for designated files with the POD. |
 |
(6) MODICON Modbus RTU MultiLink setting disabled |
 |
This setting has been disabled because MultiLink connection using the PLC Modbus RTU manufactured by Schneider (MODICON) is not possible, but the setting can be erroneously made with the editor. |
 |
(7) PLCs with ladder transfer function added |
 |
 |
Maker |
Model |
OMRON |
SYSMAC CS1/CJ1 |
|
|
 |
(8) Model supporting temperature control networks has been added. |
 |
 |
Maker |
Model |
MITSUBISHI ELECTRIC |
FR-V500 |
SUNX |
LP-300 |
LP-400 |
|
|
 |
3. Revision History (Major Revisions) |
 |
(1) V3.2.14.0 |
 |
(a) Change in setting type name for the MICREX-SX series PLC 2-Way function. |
 |
"MICREX-SX SPH/SPB series" to "MICREX-SX SPH/SPB series (IEC mode)" |
 |
 |
(b) Model with PLC 2-way connection capability added |
 |
 |
Maker |
Model |
FUJI ELECTRIC FA |
MICREX-SX SPH F mode (RS-232C) |
MICREX-SX SPH N mode (RS-232C) |
HITACHI |
HIDIC-S10/4α |
|
|
 |
 |
(c) Model supporting temperature control networks has been added. |
 |
 |
Maker |
Model |
MITSUBISHI ELECTRIC |
FR-V500 |
SUNX |
LP-F10 |
|
|
 |
 |
(d) Connectable PLCs have been added. |
 |
 |
Maker |
Model |
HITACHI |
HIDIC-S10/4α |
|
|
 |
(3) V3.2.12.0 |
 |
(a) Supported by MICREX-SX series loader "PLC Programmer Standard" |
 |
 |
(b) Operand indications changed in Keyence PLC model KV-700 and KV-1000. |
 |
The operands of input/output relays, internal utility relays and special utility relays have been changed from "CH" to "R". |
 |
 |
(c) Model with PLC 2-way connection capability added |
 |
 |
Maker |
Model |
FUJI ELECTRIC FA |
MICREX-SX SPH/SPB IEC mode (RS-233C) |
|
|
 |
 |
(d) Model supporting temperature control networks has been added. |
 |
 |
Maker |
Model |
YASKAWA CONTROLS |
E-POSI |
|
|
 |
 |
(e) Connectable PLCs have been added. |
 |
 |
Maker |
Model |
KEYENCE |
KV-1000 (Ethernet TCP/IP) |
|
|
 |
(4) V3.2.11.0 |
 |
(a) Number of correction points changed in detachable POD touch panel |
 |
The number of correction points has been changed from four to nine. |
 |
 |
(b) Switch added to delete CF card data |
 |
A delete switch has been added to the transfer menu of the local screen card menu that makes it possible to delete all of the data in a FAT-formatted CF card. |
 |
 |
(c) JPEG search switch and output of displayed JPEG File No. to memory functions added |
 |
A JPEG search switch with a flexible increment/decrement value setting has been added. A function to output the presently displayed JPEG file No. to memory has also been added. |
 |
 |
(d) Model with PLC 2-way connection capability added |
 |
 |
Maker |
Model |
HITACHI |
HIDIC-S10/2α,S10mini |
|
|
 |
 |
(e) PLCs with ladder transfer function added |
 |
 |
Maker |
Model |
FUJI ELECTRIC FA |
MICREX-SX SPB |
YOKOGAWA ELECTRIC |
FA-M3,FA-M3R |
|
|
 |
(6) V3.2.8.0 |
 |
(a) A reference memory was added to the overlap function, making it possible to control the overlap display/hide status. |
 |
 |
(b) "Periodic Write" and "Synchronous Write" were added to the table settings for the temperature control network along with a function to write the data in the PLC memory and POD internal memory to the temperature control memory. |
 |
 |
(c) The use of the SRAM cassette was made possible for the UG230. (The SRAM cassette for the UG230 will be released in August 2004.) |
 |
 |
(d) I/O monitoring of double-word units was enabled with the Mitsubishi MELSEC-Q series PLC ladder monitor function. |
 |
 |
(e) A personal name font was added to the simple POD. |
 |
 |
(f) The ladder transfer function of OMRON's CPM2C PLC was added. |
 |
 |
(g) Model supporting temperature control networks has been added. |
 |
 |
Maker |
Model |
TOHO ELECTRONICS |
TTM-000 |
|
|
 |
 |
(h) Connectable PLCs have been added. |
 |
 |
Maker |
Model |
KEYENCE |
KV-1000 |
|
|
 |