Paperless Recorder <PHR>

Paperless Recorder <PHR>
Portable type
  • Portable type

Provides flexibility and variety in the handling of record data.

Up to 9 or 18 channels for thermocouples, RTD, voltage, or current input

① Status display

Screen name, date & time, alarm information, recording status, writing status of measured data in Compact Flash, and fitting status of the card into the recorder slot.

② Time display

Indicates the recorded time and time scale.

③ Trend display

Allows you to view measured result in waveforms.

④ Digital display

Allows you to view measured values in a digital form.

⑤ Key panel

Allows you to start/stop recording, and to change the display mode or the settings.

⑥ Power indicator

Lights during the power is on, and blinks when the screen saver is working.

Specifications

General specifications Installation Panel mount or portable type
Power supply voltage 100–240 V AC, 50/60 Hz
Power consumption Approx. 47 VA (at 240 V AC)
Terminal M3 screw terminal (Open collector outputs are D-sub connectors.)
Input section Number of inputs 9 or 18 points
Measurement cycle 100 ms
Input signal Thermocouple (type B, R, S, K, E, J, T, N, W, L, U, or PN)
RTD (Pt100)
DC voltage (50 mV, 500 mV, or 5 V)
DC current (with shunt resister)
Burnout function Provided as standard for thermocouple or RTD input
Display unit Display 5.7" TFT color LCD (320 x 240 dots) with automatic display off function
Life of backlight 50,000 hours
Display contents Trend, bar graph, digital display, event summery, historical trend, parameter, parameter setting, group, analog meter, scale, total data
Recording function Storage medium CompactFlash
Recording capacity 2 GB max.
Data saving cycle Links to refreshment cycle of the trend display
Trend data Maximum and minimum values are saved.
Event data Alarm data and message data are saved.
Data format ASCII (readable by Excel)
Binary (not readable by Excel)
Storage capacity Approx. 1.5 years' worth at a display refresh cycle of 30 seconds (ASCII, 9 channels, 256 MB CompactFlash)
Memory consumption Displayed in bar graph
Recording stops when the memory is full.
Calculation function
Difference between channels, F value, integration, square root extraction
Alarm Number of settings Up to 4 alarms for each channel
Alarm type High/low limits
Indication Alarm status is displayed on digital display when an alarm occurs.
Histories are displayed in the alarm summary.
Relay contact output 10 points (option) *Not available for 18-inputs version.
Open collector output 18 points (option)
Performance Indication accuracy ±(0.15% + 1 digit) of input range
Indication resolution 0.1°C
Reference junction
compensation error
±0.5°C
Others Memory backup   Parameter settings are saved to the internal nonvolatile memory.
The clock is backed up by a built-in lithium battery.
Trend data is stored in CompactFlash with no back-up.
Option   Alarm output/DI 10 relay outputs and 5 digital inputs (Not available for 18-inputs version.),
or 18 open collector outputs and 5 digital inputs are added.
Communication Ethernet or RS485 (MODBUS) interface with 18 alarm (open collector) outputs and 5 digital inputs
Accessories Panel mount type Data viewer software, parameter loader software, panel mounting bracket, noise filter for power cable, front panel packing, instruction manual (CD-R)
Portable type Data viewer software, parameter loader software, power cable (2 m), noise filter for power cable, instruction manual (CD-R)

Recorders

Paperless Recorder <PHF>

Paperless Recorder <PHF>

Records data on CompactFlash
Thermocouple, RTD, voltage, or current input
3 or 6 points

Paperless Recorder <PHR>

Paperless Recorder <PHR>

Records data on CompactFlash
Thermocouple, RTD, voltage, or current input
9 or 18 points

Paperless Recorder <PHL>

Paperless Recorder <PHL>

Records data on CompactFlash
Thermocouple, RTD, voltage, or current input
9 or 18 points

Paperless Recorder <PHU>

Paperless Recorder <PHU>

Large size
Records data on CompactFlash
Thermocouple, RTD, voltage, or current input
9, 18, 27, or 36 points