Paperless Recorder <PHL>
- Overview

Provides flexibility and variety in the handling of record data.
Up to 9 or 18 channels for thermocouples, RTD, voltage, or current input
- Wide variety of display mode
- Large-capacity data storage
- Data viewer and parameter loader software provided as standard
- Compact design: 160 x 144 x 185 mm, 1.5 kg
- RS485 (MODBUS) (option)
- Ethernet (option)
① Status display
Screen name, date & time, alarm information, recording status, writing status of measured data in Compact Flash, and fitting status of the card into the recorder slot.
② Time display
Indicates the recorded time and time scale.
③ Trend display
Allows you to view measured result in waveforms.
④ Digital display
Allows you to view measured values in a digital form.
⑤ Key panel
Allows you to start/stop recording, and to change the display mode or the settings.
⑥ Power indicator
Lights during the power is on, and blinks when the screen saver is working.
Specifications
General specifications | Mounting method | Panel mount |
---|---|---|
Power supply voltage | 100–240 V AC, 50/60 Hz | |
Power consumption | Approx. 47 VA (at 240 V AC) | |
Terminal | M3 screw terminal (Open collector outputs are D-sub connectors.) | |
Input section | Number of inputs | 9 or 18 points |
Measurement cycle | 100 ms | |
Input signal | Thermocouple (type B, R, S, K, E, J, T, N, W, L, U, or PN) RTD (Pt100) DC voltage (50 mV, 500 mV, or 5 V) DC current (with shunt resister) |
|
Burnout function | Provided as standard for thermocouple or RTD input | |
Display unit | Display | 5.7" TFT color LCD (320 240 dots) with automatic display off function |
Life of backlight | 50,000 hours | |
Display contents | Trend, bar graph, digital display, event summery, historical trend, parameter, parameter setting, group, analog meter, scale, total data |
|
Recording function | Storage medium | CompactFlash |
Recording capacity | 2 GB max. | |
Data saving cycle | Links to refreshment cycle of the trend display | |
Trend data | Maximum and minimum values are saved. | |
Event data | Alarm data and message data are saved. | |
Data format | ASCII (readable by Excel) Binary (not readable by Excel) |
|
Storage capacity | Approx. 1.5 years' worth at a display refresh cycle of 30 seconds (ASCII, 9 channels, 256 MB CompactFlash) | |
Memory consumption | Displayed in bar graph Recording stops when the memory is full. |
|
Calculation function | Difference between channels, F value, integration, square root extraction | |
Alarm | Number of settings | Up to 4 alarms for each channel |
Alarm type | High/low limits | |
Indication | Alarm status is displayed on digital display when an alarm occurs. Histories are displayed in the alarm summary. |
|
Relay contact output | 10 points (option) *Not available for 18-inputs version. | |
Open collector output | 18 points (option) | |
Performance | Indication accuracy | ±(0.15% + 1 digit) of input range |
Indication resolution | 0.1°C | |
Reference junction compensation error |
±0.5°C | |
Others | Memory backup | Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a built-in lithium battery. Trend data is stored in CompactFlash with no back-up. |
Option | Alarm output/DI | 10 relay outputs and 5 digital inputs (Not available for 18-inputs version.), or 18 open collector outputs and 5 digital inputs are added. |
Communication | Ethernet or RS485 (MODBUS) interface with 18 alarm (open collector) outputs and 5 digital inputs | |
Accessories | Panel mount type | Data viewer software, parameter loader software, panel mounting bracket, noise filter for power cable, front panel packing, instruction manual (CD-R) |
Portable type | Data viewer software, parameter loader software, power cable (2 m), noise filter for power cable, instruction manual (CD-R) |