// =============================================================== English PXG Parameter loader Ver.3.2.3 (README.TXT) 2012-03-21 // =============================================================== Introduction : Be sure to look through this documentation before using. This documentation describes about copyright, found bugs and caution when use this software. This is a free software. All of copyrights of this software is held by Fuji Electric Co,. Ltd.(FE). User can not make copy of this software without agreement of FE. And, User can not distribute this software without agreement of FE. FE do not indemnify for any trouble and loss due to use this software. FE do not provide any support concerning this software. If you can agree with these items (README.TXT), user can use this software. Moreover, when user used this software, it is regarded that user can agree with these items (README.TXT). Update (Ver.3.0.9 -> Ver.3.2.3): 1. Ver.3.2.3 is used for New Ver.2 PXG (delivered after Jan. 2006). Ver.2 PXG has some additional functions. Ver.3.2.3 has some additional parameters on the screen, and some error display about additional parameters. If you can admit and neglect this condition, you may use this version for Ver.1 PXG. But we recomend to use Ver.3.0.9 for Ver.1 PXG. 2. Communication setteings (default value) was changed. Parity's default was changed from odd to non. If user use loader via loader comm. port, user has no need to change parity setting when startup this program. But please be caurful comm. settings when use loader via RS485 port. Hardware requirement: - PC (Dos/V) (PC-98 cannot be used) - Memory capacity: 128MB or more - Empty hard-disk capacity: 100MB or more - System environment: Windows2000 (English-language edition) Windows XP(English-language edition) Windows 7 (English-language edition) Installation: 1. Please download the Loade program (parameter loader V3.2.3) from FE web site. 2. Please double click the execution file. And, extract the program automatically. 3. Please double click the "setup.exe" file. Installation program starts up. 4. Install the loader program according to the message. 5. After finishing the installation program, choose "start menu" -> "Program" -> "ParameterLoader V3.2.3" and execute the program. Use: 1. Please connect between PC and PXG by loader cable or RS485 communication line. 2. Please select [Start menu] -> [Program] -> [Parameter Loader V3.2.3], and execute loader program. 3. Please push the "PXG" button -> "MODBUS" button. 4. Please setup communication setting at the "Comm" menu on menu-bar of loader window. 5. Please push the "OK" button. Loader program is start. In case of using loader program under off-line Please push [F12] key continuously when [OK] button push. It is necessary that hold down [F12] key continuously by boot up the program. Caution of loader connection: PXG's loader port is fixed Station=No.1, 9600bps, non-parity. Loader's default is Station=No.1, 9600bps, non-parity. If use loader via RS485, please be careful loader settings. In case of "Check target!" message is appeared: Communication setting is incorrect. Please recheck the communication settings. Cautions and footnote: 0. FE do not provide any support concerning this software. 1. FE do not inform modification and version-up concerning this software in advance. 2. This is a free software. All of copyrights of this software is held by Fuji Electric Co,. Ltd.(FE). 3. User can not make copy of this software without agreement of FE. And, User can not distribute this software without agreement of FE. 4. In case of using this software via RS485 communication, RS232C / RS485 communication converter is required. Moreover, PXG must has RS485 option. In case of using this software via Loader communication port of PXG, exclusive loader cable (Option) is required. Please ask to the agency of our company and business. 5. It may operate normally neither by other application software nor affinity with hardware. 6. Please be sure to check the specifications by specification name plate before use PXG 7. If COM-port, Baud rate and Parity settings of PC is different from PXG settings, it is not able to connect each other. (Communication error is occurred.) In case of communication error is occurred, Please re-check COM-port setting, Baud rate and Parity setting. Please be careful, PXG loader-port setting is fixed 9600bps, non-parity. 8. Baud rate and parity setup of PXG can not be rewritten via Modbus communication. 9. Please do not set the span-width of an input scale (Pvb/PvF) more than 10000. Display, setting and limit operation of an industrial value parameter may become unusual. 10. This software was developed on English environment. In case of using this software on other environment, 11. Before download, please be sure to check all the parameter setting is correct. 12. Please do not set the code without the display of an input kind to PvT. 13. Pvb/PvF, SVL/SVH, AL1L/AL1h, AL2L/AL2h, AL3 L/AL3h, PLC1/PLC2, PHC1/PHC2, AOL/AOh, PMin/PTMX etc. These parameters have Hi-Lo relations. Please avoid reverse setting. 14. Selected Modbus station No. is displayed in the title-bar, upper-left of main-window. 15. "h" of a ramp-soak parameter means Hour, and "m" means minute. 16. Cursor movement between each item of a parameter list window can be operated by the TAB key. 17. In case of selecting the deviation alarm type, no error indication is displayed when set the value less than lower-limited value. However, limit processing is performed normally. 18. When a minimum limit value is uploaded in the state of "Pvd > 0", it may be displayed red-box on a parameter name. 19. Please do not set the code of triple or more figures in Modbus station No.. 20. In case of changing "rEM" parameter from "rEM" to "LoCL" before download, PXG's SV may be different from loader's SV. In this case, please download again. So, SV is matched between PXG and loader. 21. In case of attaching current output, voltage output or re-transmission output on OUT1 or OUT2, it may be occurred the error message about TC1 or TC2 to download. But, it is not problem.