EMC filter built-in series
Three-phase 400V series
Item | Specifications | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Type (FRNF1E-4A) |
0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | ||
Applicable motor rating [kW] *1 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | ||
Rated capacity [kVA] *2 | 1.9 | 2.8 | 4.1 | 6.8 | 9.5 | 12 | 17 | 22 | ||
Voltage [V] *3 | Three-phase 380 to 480V (with AVR function) | |||||||||
Rated current [A] *4,*9 | 2.5 | 3.7 | 5.5 | 9.0 | 12.5 | 16.5 | 23 | 30 | ||
Overload capability | 120% of rated current for 1min | |||||||||
Rated frequency [Hz] | 50, 60Hz | |||||||||
Phases, voltage, frequency |
Main power supply | Three-phase, 380 to 480V, 50/60Hz | ||||||||
Auxiliary control power input | Single-phase, 380 to 480V, 50/60Hz | |||||||||
Voltage/frequency variations | Voltage: +10 to -15% (Voltage unbalance: 2% or less *7), Frequency: +5 to -5% | |||||||||
Rated input current [A] *5 | 1.6 | 3.0 | 4.5 | 7.5 | 10.6 | 14.4 | 21.1 | 28.8 | ||
Required power supply capacity [kVA] | 1.2 | 2.2 | 3.1 | 5.3 | 7.4 | 10 | 15 | 20 | ||
Braking torque [%] *6 | 20 |
|||||||||
DC injection braking | Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% | |||||||||
EMC filter unit | EMC filter | Provided (According to the compatible EMC standard, emission corresponds to class A (NE55011: 1998+A1: 1999+ A2: 2002) and immunity corresponds to 2nd ENV. (EN61800-3: 1996+A11: 2000). |
||||||||
DC REACTOR | Provided (If load of 100% is used (rated output) used, power supply ratio is above 86%.) | |||||||||
Applicable safety standards | UL508C, C22.2No.14, EN50178: 1997 (Approval pending) | |||||||||
Enclosure (IEC60529) | IP20, UL type | |||||||||
Cooling method | Natural cooling | Fan cooling | ||||||||
Weight / Mass [kg] | 6.0 | 6.3 | 6.5 | 6.9 | 6.9 | 14.8 | 14.5 | 15.2 |
*1 | Fuji 4-pole standard motor |
*2 | Rated capacity is calculated by assuming the output rated voltage as 220V for three-phase 200V series and 440V for three-phase 400V series. |
*3 | Output voltage cannot exceed the power supply voltage. |
*4 | When the carrier frequency is low, the temperature of the motor may increases rapidly or the inverter protection (current limit) may activate. When setting the carrier frequency to 1kHz or less, reduce the load to 80% of its rated value. |
*5 | The value is calculated on assumption that the inverter is connected with a power supply capacity of 500kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50kVA) and %X is 5%. |
*6 | Average braking torque without optional braking resistor (Varies with the efficiency of the motor.) |
*7 | Voltage unbalance (%) = ( MAX. voltage(V) - Min. voltage(V) ) / ( Therr-phase average voltage(V) ) x 67 (compliant with IEC61800-3) If this value is 2 to 3%, use an AC REACTOR (ACR option). |
*8 | Use the inverter at the current given in ( ) or below when the carrier frequency setting is higher than 3kHz or the ambient temperature is 40°C or higher. |