Fuji Electric Global

Global
Site Menu

Upgrading the MICREX-SX Series SPH Programming Support Tool

Log in to download the upgraded version of the programming support tool. After logging in, click the "Fe Library" button to jump to the download page.
The upgraded version of the programming support tool can be downloaded from the "Fe Library" page.

Applicable model

IEC 61131-3-compliant programming support tool: SX-Programmer

Type Name Newest version Date of upgrade
NP4H-SEDBV3 Expert(D300win) V3.6.9.16 May 2016

Upgrade service details

This new service gives the registered users of Expert (D300win) direct access to the latest version of the software through the upgrade feature on the Fuji Electric FA website. Users can download the most recent version of the software from the website at their convenience.

Name of the upgrade file for SX-Programmer: ExpertUpdateV36916.exe

Main changes in the latest version: V3.6.9.16 (May 2016)

(1) Improvement of function
  • Added the mode to exclude "comment" from search target in the global find and replace.
  • In the downloading zip project to the user ROM, add the function which can be downloaded automatically in the designated date and time.
  • In the display mode of LD/FBD program with variable comment, improve to display variable comment during monitoring.
  • In the replace function, improve to use "Replace All" button at the find direction “Up”.
(2) Problem correction
  • The problem which can't be downloaded in the multi-CPU configuration of SPH3000MG and SPH3000 was corrected.
  • In the optimization compilation mode of SPH3000, the problem that the fatal failure "WDT up error" is occurs when the program with "INT_TO_DINT" and "UINT_TO_DINT" was downloaded, was corrected.
Note)
  • The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  • This version is supported for Windows XP, Vista, 7, 8.

History of main version upgrades

  1. V3.6.8.7 (December 2015)
    1. Improvement of function
      • Added the batch replace function of more than one text in the global replace.
      • Added the function which computes the tact cycle of SX bus or E-SX bus with system configuration.
      • Improve to keep the setting of monitor display mode in the PLC information.
    2. Problem correction
      • On English O/S, the problem that "the POU size" and "the FB instance size" of compiler setting aren't set right was corrected.
      • In the optimization compilation mode of SPH3000, the problem that the ST program which reversed WORD type variable by NOT instruction doesn't normally calculate was corrected.
      • In multi-CPU configuration of SPH3000MM/MG, the problem that verify error of monitor starting is occurs at the patch POU was corrected.
    3. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
    1. Improvement of function
      • In the static analysis, added the function to display the memory allocation and word size of variable.
      • Improve in order to edit more than one project, when Expert started more than one.
      • Improve to build cross reference information automatically, when opened the project.
      • In the monitor of REAL type data, improve in order to specify the indication number of figures below the decimal point.
      • Added the function to record operational log.
      • Added the export/import function of option setting information.
      • Improve to save the setting of the POU size and the FB instance size in project file.
    2. Problem correction
      • The problem that the circuit which is under the jump instruction isn't printed on the execution order may be occurred was corrected.
      • When "F10" key was pressed to change the double-byte character, the problem that the “File” menu is chosen was corrected.
      • In the global find, when the text is searched at the input/output parameter in the user FB, the problem that the error was occurred.
      • In multi-CPU configuration of SPH3000MG, when the program of CPU0 was changed in on-line mode, the problem that the compile error was occurred on program of CPU1 was corrected.
      • The problem that PC will be in the blue screen state during USB communication was corrected.
        (When this problem occurs, please upgrade the USB communication driver.)
    3. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  2. V3.6.6.11 (July 2014)
    1. Improvement of function
      • Improve to install the USB communication driver from the program menu.
      • In the system definition, the maximum check value of the number of input-and-output of remote I/O of OPCN-1 interface module was changed into 128W from 64W.
    2. Problem correction
      • When the project of the previous version was used by V3.6.5.19, the problem that "The file error" may be occurred was corrected.
      • When the option of “Do not change the address of the variable which has been compiled last time” is ON, the problem that the compile error may be occurred was corrected.
      • In the SX control utility, the problem which cannot search an address was corrected.
    3. Note) ・ The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  3. V3.6.5.19 (March 2014)
    1. Enhancing of online POU change function
      • Improve to add the variable and the FB instance even when exceeding the reserve size.
        Target PLC : SPH3000MM(NP1PU2-048E, NP1PU2-256E), SPH3000MG(NP1PU1-256NE)
      • In the optimization compilation mode, improve to add the variable and the FB instance even when exceeding the reserve size. Target PLC : All of SPH3000 series
      • Improve to add array / structure data type.
        Target PLC : SPH2000(NP1PM-256H), All of SPH3000 series
    2. Added compatible with Windows 8.
      For using on Windows 8, the installation of Microsoft [.NET Framework 3.5] is required.
      Note)
      For using on Windows 8, the installation of Microsoft [.NET Framework 3.5] is required.
      Download [.NET Framework 3.5] from Microsoft’s website shown below and install it.
      http://msdn.microsoft.com/en-us/aa496123
    3. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  4. V3.6.4.8 (October 2013)
    1. Improvement of graphic editor function
      • In the SFC program editor, improve to display the error when the result of the copy and the movement operation does not suit the mapping rule of the SFC symbol.
      • Improve to become the compile error when an illegal character is input to the I/O address of the variable property dialog.
    2. Problem correction
      • In the FBD editor, the problem that the circuit might collapse was corrected when the symbol was copied and moved for the keyboard operation.
      • In the English version, the problem that the compression project was not able to be up-loaded from UROM was corrected.
      • In the ST work-sheet, the problem that the error occurred when the line including the array was dragged while monitoring was corrected.
    3. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  5. V3.6.3.5 (June 2013)
    1. Enhancing of online function
      • Added the function to save download history information in PLC when download and patch POU of program.
        (Supported PLC:SPH2000 and SPH3000)
      • In the case of disagreements of the program in PLC and in the project, improved it not to execute the patch POU of online.
    2. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  6. V3.6.2.24 (March 2013)
    1. Support added for the SPH3000 new CPU modules
      SPH3000 (NP1PM-128E), SPH3000MG (NP1PU1-256NE)
    2. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  7. V3.6.1.3 (December 2012)
    1. Enhancing of global variable number
      The maximum use number of global variables a resource has been enhanced from 15000 to 100000.
    2. Improvement of ladder editor function
      • Added insert function of symbol by typing the instruction name and the variable name.
      • Added the function to arrange connected line automatically.
      • Improve to insert the instruction and the variable from the Edit wizard and the variable worksheet by the drag & drop operation.
      • Added the function to display the address and the comment with the ladder symbol.
    3. Other Improvement
      • Added the function to save the registered information of the shortcut key in the file.
      • Added the function to set on read-only attribute for each variable group in the global variable worksheet.
    4. Note)
      The project file used with this version cannot be opened on the previous version (before V3.5.4.14).
  8. V3.5.4.14 (June 2012)
    1. Enhancing of online POU change function
      Improve to add the variable and the FB instance even when exceeding the reserve size.
      • Target PLC : SPH2000(NP1PM-256H), SPH3000(NP1PU-048E, NP1PU-256E)
  9. V3.5.3.18 (September 2011)
    1. Windows 7 (64bits) compatibility
      • Added compatible with Windows 7 (64bits).
      • Added the USB driver for Windows 7 (64bits).
      Please install the USB driver by [Windows Device Manager] when you use the communication of USB.
  10. V3.5.2.36 (July 2011)
    1. Support added for the SPH3000 new CPU modules SPH3000MM and E-SX bus I/O unit.
    2. Added compatible with Windows 7 (32bits).
    3. Problem correction
      In the SPH3000 series, the following problems of the optimization compilation have been corrected.
      • In the ladder circuit, when the AND block and the OR block are combined and used, the operation might not be correctly executed.
      • In the ST language, the operation of a minus value type conversion instruction might not be correctly executed.
  11. V3.5.1.15 (April 2010)
    1. Enhancing of watch window function
      Added the writing function of the recipe value and the file saving function of watch window information.
    2. Enhancing of POU property function
      Added the batch change function of property and the POU comment functions.
    3. Improvement of display function of graphic editor
      Improved the Non-display of the VAR_EXTERNAL variables and Non-display of the terminal of the FB functions.
    4. Improvement of online debugging function
      Improved the operation of the online debugging dialog.
  12. V3.5.0.0 (March 2009)
    1. Addition and expansion of LD/FBD-V2-compatible editor functions
      Increased the number of undo times and made functional improvements, including improvements in the FB/function replacement function.
    2. Improvement in editor setting function
      Improved the graphic editor and LD/FBD editor setting functions.
    3. Addition and expansion of SFC editor functions
      Made functional expansions including the expansion of SFC branch reassignment function and active step display function.
    4. Support added for the SPH3000 CPU modules.
    5. Added compatible with Windows Vista.
  13. V3.4.5.0 (November 2008)
    1. Expansion of SPH300-compliant functions.
      Added support for the SPH300 ‘Waiting time mode for structure check' function and ‘Non fatal failure User ROM recognition error display' function.
    2. Expansion of SPB/ board controller -compliant functions.
      Added support for the SPB/ board controller ‘Updating current value setting' in the high counter definition.
    3. Problem correction
      In the SPH2000 series, when you used user FB by two steps or more nesting and the BOOL type variable was connected with the terminal VAR_INOUT of user FB, the problem which the operation was not correctly executed has been corrected.
  14. V3.4.4.1 (September 2008)
    1. Problem correction
      In the program (project) verify function with CPU of the SPH2000 series, the verify problem when the number of program steps is the same has been corrected.
  15. V3.4.4.0 (May 2008)
    1. Expansion of SPH2000-compliant functions.
      Added support for the SPH2000 CSV mail client, general-purpose communications settings by users, and parallel interface connection with a Programmable Operation Display (POD).
    2. Added support for @E.Integrator
  16. V3.4.3.0 (November 2007)
    1. Expanded COM port number of communication setting to 256 ports.
    2. Expansion of SPH200-compliant function
      Adding the function that enables to select latency mode to check configuration from "configuration correspondence/set time" in the SPH200 system properties.
  17. V3.4.2.0 (August 2007)
    1. Expansion of board controller-compliant function
      • A function enabling a user to select rising-edge or falling-edge in the logic system of the signal to the high-speed Input connector has been added to the board controller's CPU parameters.
      • A function to externally set a link station address has been added to the simplified CPU link function of the board controller's CPU parameter.
      • The day of the week data and the calendar write request have been added to the board controller's calendar information.
    2. Improved failure diagnostic function
      A "Failure analysis" function to automatically analyze and display the failed state has been added to the SPH300 failure diagnostic function.
        * To use the "Failure analysis" function, the installation of Microsoft [.NET Framework 2.0] is required. Please see Item 6. Upgrading procedure in this notice.
  18. V3.4.1.0 (May 2007)
    1. Supports a mode of No detection of battery error
      Adding the battery error detection function for CPU parameters in SPB series.
    2. Enhanced LED monitor indication
      Adding display function of existence of zero suppression in decimal display and Standard decimal point expression in real number.
  19. V3.4.0.0 (February 2007)
    1. Improving basic functions
      Various basic functions, including variable editor's coordination with Microsoft Excel, variable property dialog box, automatic update of cross-reference function, project comparison, and the element registration in data watch window, have been improved.
    2. Improving ladder diagram editor
      Such functions as alignment of the bus on the left, worksheet division, and the jump to circuit comment have been improved.
    3. Supports SPH300 non-user ROM-based operation mode
    4. Supports SPH2000 redundant CPU module (NP1PM-256H)
    5. V3.3.7.1 problem correction
      A problem that if the capacity of a global variable sheet is large, the Expert was forcibly terminated when you intended to execute the creation of cross-reference, has been corrected.
  20. V3.3.7.1 (December 2006)
    1. V3.3.7.0 problem correction
      With models of SPH200 and SPB, a problem that showed an application error when you operated the download of project, has been corrected.
  21. V3.3.7.0 (November 2006)
    1. Board controller support ― T-Link optional card
  22. V3.3.6.0 (October 2006)
    1. IP address list: Network device search function
      A network device search function has been added to IP address list function.
    2. Offline ZIP file save function
      A function to save ZIP files on the computer's hard disk has been added.
  23. V3.3.5.0 (August 2006)
    1. Servo system FALDIC ALPHA5 support
    2. V3.3.4.1 problem correction
      With models other than SPH300EX, a problem that showed a compile error if the end of variable name was ‘_E' when you specified a global variable for AT, has been corrected.
  24. V3.3.4.1 (July 2006)
    1. High performance CPU module SPH300EX(NP1PS-74D) support
    2. V3.3.3.0 problem correction
      With SPH2000(NP1PM-48E/NP1PM-256E), a problem that the access of FTP was disabled, has been corrected.
  25. V3.3.3.0 (May 2006)
    1. Enhancing password functions
      A function that lets the user set the scope of access restrictions has been added for use with the function that was added in V3.3.2.0 to set restrictions on PLC online operation. A password can now be used to set the restricted functions for each access level.
    2. Adding a ladder program printing function with cross-references
      A function was added that allows project printing to print cross-reference data on the same page as the program.
    3. Improving the dialog box for defining variables
      The default display for the "Display all worksheet variables" function, for setting global variable groups in the dialog box for defining variables, has been changed to "With setting".
    4. Tool chip display of variable data
      The data format, initial value, comments, etc. for each variable can be displayed in tool chip format on the worksheet.
  26. V3.3.2.0 (January 2006)
    1. Expansion of password functions
      A function has been added to set restrictions on PLC online operation.
      By using this function and setting a password for access authentication, PLC operation can be restricted on three levels (i.e., level 1, level 2, and level 3).
    2. Batch resetting of variable display mode
      A reset function has been added to return the variable display mode settings in the LD/FBD worksheet to the default display settings in a single operation.
    3. SPH300 firmware support (V**65)
      • System fail-soft startup time reduction function
      • Continuous operation under forced settings
  27. V3.3.1.0 (November 2005)
    1. Board controller support
  28. V3.3.0.0 (August 2005)
    1. System definition: Enhanced non-mounted operation
      Mounted and non-mounted modules can be switched with just one click. And, with just one click of the mouse in the batch non-mounted setting function, modules selected on the configuration tree and modules below that hierarchy can be set for batch dismounting or the setting can be cancelled.
    2. The new series CPU module SPH2000 is supported.
  29. V3.2.1.0 (June 2005)
    1. Change of the product name
      The name of the product has been changed from "D300win" to "SX-Programmer Expert (D300win)".
    2. Improved variable editor
      The variable editor has been improved to support Microsoft Excel, to enhance edit operation and batch insertion of variables.
    3. Improved project editing
      The extraction of compressed project files (ZWT files) and the project tree editor function have been improved.
    4. Improved printer functions
      Page print setting in project printing and loop back printing for variable worksheets have been improved.
    5. Supports SPH300 I/O area expansion
      The SPH300 (V**64 or later) I/O area expansion function is supported.
  30. V3.2.0.0 (April 2005)
    1. Upgraded kernel functions
      • Improved dialog box for defining variables
      • Improved dialog box for defining functions and function blocks
      • Improved variable worksheet operations
      • Added POU group functions
      • Expanded POU import/export functions
      • Enhanced multi-user support functions
      • Expanded sampling trace functions
      • Improved message windows
    2. Added a project history function
      A function has been added to log project histories (including POU changes) after every successful download.
    3. Improved failure diagnostic function
      The documentation on the part of the memory dump in the RAS display screen has been improved.
  31. V3.1.4.0 (October 2004)
    1. Maximum processor link module configuration expanded
      The maximum connectable number of processor link modules (P-link or FL-net) has been increased to 8 (eight).
    2. Added system definition settings
      A setting for booting the system without CPU" 0" has been added to the system operation definition settings in the system definition. An "Expansion setting" has been also added to the fail-soft startup definition in the system properties.
  32. V3.1.3.0 (August 2004)
    1. Supports sampling trace function on SPH CPU board
      High-precision sampling trace startup is supported when this programming support tool is connected to a CPU board (NP3PS-SX1PCS74 V**63) with sampling trace function mounted.
  33. V3.1.2.0 (May 2004)
    1. Supports 8 k-step POUs of SPH300 (V**62 or later).
    2. Improved the SX control utility
      Online connection by the message manager is supported. This enables Expert (D300win) and the control utility to communicate simultaneously from a single port.
  34. V3.1.1.0 (December 2003)
    1. Sampling trace function support
      Supports the sampling trace function available with the SPH300 (V**61 or later).
    2. Improved online functions
      The failure diagnostic function has been enhanced, in which the POU name corresponding to the POU number can be displayed by the system fatal fault information.
  35. V3.1.0.0 (June 2003)
    1. Compact PLC SPB support
      The IEC 61131-3 compliant program for SPB series PLC is supported.
    2. SPB system software utility
      The system software (firmware) for SPB basic units can be rewritten to SX mode (IEC 61131-3 -compliant programming language).
    3. Enhanced SX control utility functions
      Data editing functions have been expanded; including time and text string formats. Backup file uploading has been enhanced, editing functions expanded, and a tab delineated text format added.
  36. V3.0.0.0 (December 2002)
    1. New ladder editor
      The ladder editor, which is used to display and edit ladder worksheets, has been improved from the previous free-layout format to a grid-frame fixed format. The new editor simplifies programming by key operation.
    2. Table format for variable worksheets
      The new table format for variable worksheets (local/global) makes it easier to organize variables.
    3. Project protect function added
      Security has been increased by allowing detailed protection by means of a project password.
    4. Improved fault diagnosis function
      Fault diagnosis has been simplified by allowing fault data analysis while confirming constituent data.

5. Backward compatibility

The following table shows the project compatibility for the upgrade.。

  Projects created with previous version Projects created with V3.6.9.16
NP4H-SEDBV3 (previous version) ×
NP4H-SEDBV3 (V3.6.9.16)

Note) Projects used with the new version cannot be opened on the previous version (before V3.5.4.14).

Upgrading procedure

  1. Create a new folder on the computer's hard disk.
  2. Download the V3.6.9.16 upgrade file (ExpertUpdateV36916.exe) to the new folder.
  3. Double click the downloaded file. (The upgrade is a self-extracting file.)
  4. The file will be extracted to the same folder.
  5. Double click the extracted Setup.exe file.
  6. Follow the prompts from the installer program to upgrade the software.
  7. Expert (D300win) will start up when the installation is completed. Check Info from the Help menu to make sure the version number is V3.6.9.16.
    * NOTE
    To use on Windows Vista and Windows7, administrator's right is necessary for the installation.
    Install the program according to the procedure below.
    • Select "Setup.exe" in the Explorer window after extracting the update file, and right-click this.
    • Select "As the administrator" from the right-clicking menu.
    • Following the instructions from the installer to install the program.

Upgrading precautions

  1. Make sure that NP4H-SEDBV3/Expert (D300win) is already installed on the computer prior to upgrading the software.
  2. The software cannot be upgraded if the computer does not have Expert (D300win) version 3.0.0.0 or later already installed on it.
  3. Do not begin the installation if the upgrade file is not exactly the same size as the file that was downloaded. If they are not the same size, throw all of them into the trash and download the upgrade file again.
  4. Be sure to quit all programs that are currently running (e.g., Expert (D300win), SX control utility, or message manager) prior to the installation.
  5. If the installation fails due to an error, try to install the software again. If the installation fails again, re-install the previous version of Expert (D300win) from the setup CD and then try to install the upgrade software again.

Log in to download the upgraded version of the programming support tool. After logging in, click the "Fe Library" button to jump to the download page.
The upgraded version of the programming support tool can be downloaded from the "Fe Library" page.